Jlab Export is a leading LP6 Ventilator Manufacturer,and suppliers in Africa, LP6 Ventilator Uruguay (Montevideo), LP6 Ventilator Uzbekistan (Tashkent), LP6 Ventilator Venezuela (Caracas), LP6 Ventilator Vietnam (Hanoi), LP6 Ventilator Yemen (Sana'a), LP6 Ventilator Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)
LP6 Ventilator
Mode: Standby, Assist/Control, SIMV or Pressure Cycle
Low Pressure Alarm: Set limit for Low Pressure alarm 2 to 32
cmH2O in increments of 2 cmH2O
High Pressure Alarm Limit: (Assist/Control, SIMV Modes) or limit
for Pressure Cycle mode: 15 to 90 cmH2O in increments of 5 cmH2O
Volume: Push-to-turn knob: 100 to 2200 mL
Breath Rate: 1 to 20 BPM in increments of 1 BPM and 22 to 38 BPM in increments of 2 BPM
Inspiratory Time: 0.5 to1.0 sec in increments of 0.1 sec; 1.2 sec; and 1.5 to 5.5 sec in increments of 0.5 sec
Breathing Effort: Push-to-turn knob sets pressure level to detect breathing effort (-10 cmH2O/hPa to +10 cmH2O)
Specifications:
Front Panel Input |
Patient Pressure: Port for connection to proximal pressure line of |
Front Panel Output |
Patient Air: 22 mm x 15 mm tube for connection to bacteria filter |
Indicators, Normal Events |
Patient Pressure Meter: Displays patient pressure -10 to +100 cmH2O; can |
Audible Alarms |
Pulsating Tone: Low Pressure/Apnea; Low Power, High Pressure, |
Rear Panel Controls |
AC Circuit Breaker: Internal to AC power switch |
Rear Panel Inputs |
Inlet Filter: Intake for patient air; screw off cap for filter change |