Brodie Starling Kymograph Manufacturer,Supplier and Exporter in India
Product Code : EL-PALE-2346
Jlab Export is a leading Brodie Starling Kymograph Manufacturer,and suppliers in India
The Brodie Starling kymograph carries a long loop of paper between a 6 in x 11 in main cylinder and an outer arm. It is built for records that run far longer than one turn of a drum. A crown wheel on the shaft drives the cylinder, and a spring-loaded device frees it for turning by hand. The paper length can be set from 60 in to 66 in.
Specifications
| Main cylinder | 6 in x 11 in, driven through a crown wheel on the shaft |
| Hand turning | Spring-loaded release |
| Paper length | Variable from 60 in to 66 in, outer arm moving in a slot in the bed |
| Stand | Rigid cast iron, raised and lowered by a large screw |
| Fine adjustment | Returns the outer arm to the same position after a paper change |
| Optional accessories | Double time marker, mercury manometer, smoking and varnishing apparatus, smoking burner |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Long-Record Experiments in Physiology
Long paper suits experiments that last a whole session. In experimental pharmacology, a mercury float manometer from the Manometers range records blood pressure while a series of drug responses is compared on one sheet. Institutions run such animal work under the approval of their animal ethics committee, and many courses now use simulations alongside it.
Human practicals use the same drum. A Pneumograph Stethograph joined to one of the Tambours writes chest movements during quiet breathing, breath holding and recovery after exercise, all on one continuous record.
Frequently Asked Questions
Why use a long paper kymograph instead of a single drum?
A single drum gives one turn of paper, which fills quickly even at slow speeds. The loop between the main cylinder and the outer arm gives 60 in to 66 in of paper. A long blood pressure or breathing record then stays on one sheet.
How is the paper changed without upsetting the set-up?
Slacken the loop by moving the outer arm, fit the new smoked paper, then bring the arm back. The fine adjustment returns the outer arm to the same position as before, so the paper runs on the same line as the last record.
Can the drum be turned by hand?
Yes. A spring-loaded device frees the cylinder from the crown wheel drive so it can be turned by hand. This helps when lining up the writing points before a record or moving the paper on between runs.
Why does the stand have a large height screw?
The screw raises and lowers the drum on its cast iron stand. That brings the paper to the height of the levers and the manometer float, instead of moving every stand on the bench.
Which accessories can be ordered with it?
The options are a double time marker, a mercury manometer, separate smoking and varnishing apparatus and a smoking burner. The time marker writes the time trace, and the other items prepare and fix the smoked paper.
Other Kymographs and Recording Drums
- Student Electrical Kymographs
- Student Kymographs Digital
- Universal Kymograph With Inbuilt Stimulator
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 12 November 2026