• +91-85699-09696

Heart Lever Starling Manufacturer,Supplier and Exporter in India

Heart Lever Starling

Product Code : EL-PALE-2366
Jlab Export is a leading Heart Lever Starling Manufacturer,and suppliers in India

A Starling heart lever writes the beat of a frog heart on a kymograph drum. It is a very light lever on a fine spring. A thread from a heart clip on the apex of the ventricle lifts it at each beat, and the spring brings it back. This one has a nickel frame, a nickel-silver spring and a notched steel lever. Its after-load lever has supporting screws and holes for attaching muscles.

Specifications

FrameNickel
SpringNickel-silver
LeverNotched steel
After-load leverSupporting screws and holes for attaching muscles
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Frog Heart Practicals on the Drum

The first record is the normal cardiogram. One of the Heart Clips holds the apex, its thread runs up to the lever, and the writing point traces each beat on a slow Kymograph drum. Students count the rate and pick out the atrial and ventricular parts of each beat.

Next comes the effect of temperature. Warm and then cold Ringer solution is run over the heart, and students compare rate and height of beat on one sheet. Changing the ions in the Ringer solution shows how calcium and potassium alter the beat. An isolated heart can be studied in a Frog Heart Chamber, which has fitments for a heart lever. These practicals run under the approval of the animal ethics committee.

Frequently Asked Questions

How tight should the thread from the heart be?
Just tight enough to lift the lever level without pulling the heart out of place. A slack thread loses part of each beat, and a tight one stretches the ventricle and changes its force.

Why does each beat show two waves on the trace?
The atria contract a moment before the ventricle. Their small wave comes first and the taller ventricular wave follows. A slight extra bump may come from the sinus venosus, where the beat starts.

Why does the heart beat so slowly at the start?
A cold frog heart beats slowly. Its rate rises as it warms toward room temperature, so let the record settle before you take control readings. Keep the heart moist with Ringer solution throughout.

What are the holes and screws on the after-load lever for?
The holes let you tie the thread at a chosen distance from the pivot, which sets the size of the trace. The supporting screws hold the lever at rest, so a muscle tied to it takes the load only as it contracts.

Other Levers and Recording Parts

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us