• +91-85699-09696

categories

Stirrers Manufacturer, Suppliers and Exporter in India

Jlabexport is a leading Stirrers Manufacturer,and suppliers in India, United States, Indonesia, Brazil, Bangladesh, Mexico, Japan, Egypt, Philippines, Democratic Republic of the Congo, Vietnam, Iran, Turkey, Tanzania, United Kingdom, France, South Africa, Italy, Kenya, Colombia, Sudan, Uganda, South Korea, Argentina, Afghanistan, Yemen, Angola, Morocco, Poland, Uzbekistan, Mozambique, Malaysia, Ghana, Saudi Arabia, Peru, Madagascar, Côte d’Ivoire, Cameroon, Niger, Venezuela, Australia, Syria, Mali, Burkina Faso, Sri Lanka, Malawi, Zambia, Chad, Kazakhstan, Somalia, Chile, Senegal, Ecuador, Cambodia, Zimbabwe, Guinea, Benin, Rwanda, Burundi, Bolivia, South Sudan, Tunisia, Haiti, Belgium, Dominican Republic, Jordan, United Arab Emirates, Honduras, Tajikistan, Papua New Guinea, Portugal, Togo, Sierra Leone, Belarus, Laos, Turkmenistan, Libya, Kyrgyzstan, Nicaragua, Paraguay, Bulgaria, Serbia, Republic of the Congo, Lebanon, Liberia, Central African Republic, Palestine, Oman, Mauritania, New Zealand, Costa Rica, Kuwait, Panama, Croatia, Georgia, Eritrea, Mongolia, Uruguay, Qatar, Namibia, Bosnia and Herzegovina, Moldova, Armenia, Gambia, Jamaica, Lithuania, Albania, Gabon, Botswana, Lesotho, Guinea-Bissau, Slovenia, Equatorial Guinea, Latvia, North Macedonia, Bahrain, Trinidad and Tobago, Timor-Leste, Cyprus, Estonia, Eswatini, Mauritius, Djibouti, Fiji, Comoros, Solomon Islands, Guyana, Bhutan, Luxembourg, Suriname, Montenegro, Malta, Maldives, Cabo Verde, Brunei, Belize, Bahamas, Iceland, Vanuatu, Barbados, São Tomé and Príncipe, Samoa, Saint Lucia, Kiribati, Seychelles, Grenada, Saint Vincent and the Grenadines, Antigua and Barbuda.

Last updated: 14 November 2026

What Are Laboratory Stirrers and Stirrer Fittings?

The stirrers in this range are overhead stirrer shafts and the fittings that carry a shaft into a flask. An overhead motor turns the shaft, and its blade mixes thick liquids, suspensions and reaction mixtures that a magnetic bar cannot move well. Chemistry teaching labs and research labs fit them to round bottom and multi-neck flasks. The range has seven items: anchor, collapsible paddle, fixed paddle and link shafts on 6 mm or 11 mm shafts, a ground-sleeve gland, a replacement sleeve with screw cap and stirrer guides. JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India, makes all seven.

Request a quotation  |  Compare the stirrer shafts  |  See the tasks covered

Which Items Are in the Stirrers Range?

GroupItemsWhat it covers
Stirrer Shafts4Anchor, folding paddle, fixed paddle and link blades on shafts from 6 mm x 450 mm to 11 mm x 750 mm, with blades extending from 50 mm to 195 mm.
Glands, Sleeves and Guides3A gland with a B19 cone and a spare screw-cap sleeve for 6 mm shafts, and stem guides for 6 mm and 11 mm shafts with B9, B19 and B24 joints.

Compare Stirrer Shafts and Fittings by Size

Each table sets the items of one group side by side, with the sizes given on each product page. A shaft size is written as diameter x length.

Stirrer Shafts (4)

StirrerBladeShaft diameterShaft lengthsExtended blade length
Stirrer, AnchorAnchor6 mm and 11 mm450 and 600 mm (6 mm); 750 mm (11 mm)195 mm on 6 x 450 mm; 140 mm on 6 x 600 mm and 11 x 750 mm
Stirrer, Collapsible PaddleFolding paddle6 mm450 mm70 mm
Stirrer, Fixed PaddleFixed paddle6 mm and 11 mm600 mm (6 mm); 750 mm (11 mm)50 mm on 6 mm; 80 mm on 11 mm
Stirrer, LinkLink6 mm450 and 600 mm75 mm

Glands, Sleeves and Guides (3)

FittingFor shaftJointThread sizeStem length
Stirrer Gland, Ground Sleeve6 mmB19 cone14Not listed
Replacement Sleeve with Screw Cap6 mmNot listed (screw cap)14Not listed
Stirrer Guides6 mmB19 socket, B9 coneNot listed250 mm
Stirrer Guides11 mmB24 socket, B24 coneNot listed350 mm

How to Choose Stirrer Shafts and Fittings

  • Shaft diameter first: The gland, the replacement sleeve and the 250 mm guide take 6 mm shafts. Only the 350 mm guide takes the 11 mm anchor and fixed paddle shafts.
  • Narrow flask necks: The Stirrer, Collapsible Paddle folds in line with its shaft to pass a narrow neck, then opens to a 70 mm span. The fixed paddle needs an opening wider than its blade.
  • Thick mixtures and settling solids: The anchor blade sweeps close to the wall and base of a round vessel. Paddle and link blades suit thinner liquids.
  • Shaft length: Measure from the motor chuck to just above the vessel base. Take 450 mm for flasks close under the motor, and 600 mm or 750 mm for tall flasks or when a guide or adapter raises the gland.
  • Joints: Match the gland cone (B19) or the guide cone (B9 or B24) to the socket on the flask neck, and the guide socket to the fitting on top.
  • Spares: The replacement sleeve renews a worn 6 mm sleeve with the same thread size 14, so the rest of the set-up stays in service.

Tasks Covered by the Stirrers Range

TaskApparatus
Stirring a reaction in a round bottom flask through a narrow neckStirrer, Collapsible Paddle, Stirrer Gland, Ground Sleeve
Keeping solids suspended in a slurry or a thick mixtureStirrer, Anchor
Mixing larger volumes in vessels with a wide neck or lid openingStirrer, Fixed Paddle
Stirring in tall flasks or set-ups where the gland sits higherStirrer, Link, Stirrer, Anchor
Sealing and guiding the shaft entry on a jointed flask during stirring under refluxStirrer Gland, Ground Sleeve, Stirrer Guides
Renewing a worn stirrer sleeveReplacement Sleeve with Screw Cap

Who Uses Overhead Stirrer Shafts and Guides?

Organic chemistry teaching labs, research labs and process development labs use them for stirred reactions in jointed flasks. Laboratory technicians use the glands, guides and spare sleeves when they build and maintain stirred set-ups.

Ordering, Minimum Quantity and Dispatch

PointDetail
Minimum order quantity50 units for each item
Dispatch timeUsually 3–5 working days
Pack quantityEach (sold individually)
How to enquireChoose the size and press Add To Cart on a product page, or send the item names, sizes and quantities through the contact page
Tenders and OEM supplySee laboratory tenders
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab), Ambala, India

Related Ranges in Lab Glassware

Stirrers is part of Lab Glassware. These ranges hold the flasks, condensers and joint pieces that a stirred set-up is built from.

RangeHow it relates
FlasksRound bottom flasks with two or three necks, which take a stirrer in the centre neck
CondensersLiebig, Allihn, coil and double surface condensers for reflux on a stirred flask
Test Tubes and Thermometer PocketsThermometer pockets with a B14 or B19 cone for a side neck, and drying tubes
Screwthreads, Discs and JointsSingle cones and sockets, screwthread and flange joints, and joint clips
Screw Caps, Stoppers and StopcocksPlastic caps, stoppers and stopcocks for the other necks of the flask
Beakers and FlasksBorosilicate beakers and flasks for open stirring and mixing

Frequently Asked Questions

When is an overhead stirrer shaft needed instead of a magnetic bar?
Use an overhead shaft when the mixture is thick, carries heavy solids or fills a large vessel. A magnetic bar can stall or lose coupling in such mixtures, while a motor-driven shaft keeps the blade turning at the set speed.

Which blade suits a thick or viscous mixture?
An anchor blade suits thick mixtures and settling solids, because it sweeps close to the wall and base. Paddle and link blades suit thinner liquids. The 11 mm shafts are stiffer than the 6 mm shafts for heavier work.

How wide should the blade be compared with the flask?
The blade should reach well across the vessel but still clear the walls as it turns. Compare the extended blade length with the inside width of the flask at blade height. A folding paddle must also pass the neck before it opens.

Why should stirring start at a low speed?
A fast start can throw liquid up the walls, pull air into the mixture and form a deep vortex. It can also whip a shaft that is out of line against the neck. Start slowly, check that the shaft runs true, then raise the speed.

Do the flask and the motor both need clamping?
Yes. Clamp the flask at its neck and fix the motor firmly to the same stand, so the shaft stays in line with the gland. A flask that is held loosely, or only by joint clips, can rock and crack at the joint.

Should the stirrer gland joint be greased?
Give the cone a thin film of joint grease so it does not seize in the socket. Then turn the shaft by hand before switching on, to check that it runs freely in the sleeve.

Request a Quote

Name the blade type, the shaft diameter and length, any glands, sleeves or guides, and the quantity of each, then send the list through the contact page or with Add To Cart on the product pages.

Stirrer, Anchor

Stirrer, Anchor

Product Code : EL-S-1687

This Stirrer, Anchor is an overhead stirrer shaft with an anchor blade, made with 6 mm or 11 mm shafts from 450 to 750 mm long.

View Details
Stirrer, Collapsible Paddle

Stirrer, Collapsible Paddle

Product Code : EL-S-1688

This Stirrer, Collapsible Paddle has a 6 mm x 450 mm shaft with a folding paddle that opens to 70 mm inside a flask.

View Details
Stirrer, Fixed Paddle

Stirrer, Fixed Paddle

Product Code : EL-S-1689

This Stirrer, Fixed Paddle is an overhead stirrer shaft with a non-folding paddle, made as 6 x 600 mm or 11 x 750 mm.

View Details
Stirrer, Link

Stirrer, Link

Product Code : EL-S-1690

This Stirrer, Link is an overhead stirrer shaft with a 75 mm extended blade on a 6 mm shaft, 450 mm or 600 mm long.

View Details
Stirrer Gland, Ground Sleeve

Stirrer Gland, Ground Sleeve

Product Code : EL-S-1691

This Stirrer Gland, Ground Sleeve takes a 6 mm stirrer shaft and has a B19 cone and thread size 14 for fitting into a flask neck.

View Details
Replacement Sleeve with Screw Cap

Replacement Sleeve with Screw Cap

Product Code : EL-S-1692

This Replacement Sleeve with Screw Cap has a 6 mm bore for a 6 mm stirrer shaft and thread size 14, matching the Stirrer Gland, Ground Sleeve.

View Details
Stirrer Guides

Stirrer Guides

Product Code : EL-S-1693

These Stirrer Guides keep an overhead stirrer shaft aligned and come with 250 mm or 350 mm stems for 6 mm or 11 mm shafts.

View Details

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us