Laboratory Glassware Adapters Manufacturer, Suppliers and Exporter in India
Jlabexport is a leading Laboratory Glassware Adapters Manufacturer,and suppliers in India, United States, Indonesia, Brazil, Bangladesh, Mexico, Japan, Egypt, Philippines, Democratic Republic of the Congo, Vietnam, Iran, Turkey, Tanzania, United Kingdom, France, South Africa, Italy, Kenya, Colombia, Sudan, Uganda, South Korea, Argentina, Afghanistan, Yemen, Angola, Morocco, Poland, Uzbekistan, Mozambique, Malaysia, Ghana, Saudi Arabia, Peru, Madagascar, Côte d’Ivoire, Cameroon, Niger, Venezuela, Australia, Syria, Mali, Burkina Faso, Sri Lanka, Malawi, Zambia, Chad, Kazakhstan, Somalia, Chile, Senegal, Ecuador, Cambodia, Zimbabwe, Guinea, Benin, Rwanda, Burundi, Bolivia, South Sudan, Tunisia, Haiti, Belgium, Dominican Republic, Jordan, United Arab Emirates, Honduras, Tajikistan, Papua New Guinea, Portugal, Togo, Sierra Leone, Belarus, Laos, Turkmenistan, Libya, Kyrgyzstan, Nicaragua, Paraguay, Bulgaria, Serbia, Republic of the Congo, Lebanon, Liberia, Central African Republic, Palestine, Oman, Mauritania, New Zealand, Costa Rica, Kuwait, Panama, Croatia, Georgia, Eritrea, Mongolia, Uruguay, Qatar, Namibia, Bosnia and Herzegovina, Moldova, Armenia, Gambia, Jamaica, Lithuania, Albania, Gabon, Botswana, Lesotho, Guinea-Bissau, Slovenia, Equatorial Guinea, Latvia, North Macedonia, Bahrain, Trinidad and Tobago, Timor-Leste, Cyprus, Estonia, Eswatini, Mauritius, Djibouti, Fiji, Comoros, Solomon Islands, Guyana, Bhutan, Luxembourg, Suriname, Montenegro, Malta, Maldives, Cabo Verde, Brunei, Belize, Bahamas, Iceland, Vanuatu, Barbados, São Tomé and Príncipe, Samoa, Saint Lucia, Kiribati, Seychelles, Grenada, Saint Vincent and the Grenadines, Antigua and Barbuda.
Last updated: 20 November 2026
What Are Laboratory Glassware Adapters?
Laboratory glassware adapters are short glass pieces with ground cones, sockets, screw threads or tubing ends that join jointed apparatus whose fittings do not match. Chemistry teaching and research labs use them to add necks to a flask, step a joint up or down, run rubber tubing from a joint, shut a line with a stopcock and collect distillate. The range holds 20 adapters: 18 in eight sub-ranges sorted by geometry, and two listed directly here. Each page gives the cone and socket sizes made. JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India, makes all of them.
Request a quotation | Compare the adapters by joint size | See the tasks covered
Which Adapters Are in the Laboratory Glassware Adapters Range?
| Group | Items | What it covers |
|---|---|---|
| Adapters Multiple | 3 | One cone that fits a flask neck and gives two or three sockets: two necks, one parallel and one 45° neck, or two parallel and one 45° neck. |
| Adapters Cone | 2 | A ground cone with a rubber tubing connection, straight or at a right angle, in cone sizes B10 to B34. |
| Adapters Vertical | 2 | Sloping and delivery patterns, each with a B19 cone and a B19 socket. |
| Adapters Receiver | 3 | Receivers for distillation: a Perkin receiver with all-glass taps, a vacuum receiver for four 100 ml flasks and a vertical receiver with a vacuum connection. |
| Reduction and Expansion Adapters | 2 | Joints stepped down (cone larger than socket, 19 pairs, such as B24 cone to B19 socket) or stepped up (cone smaller than socket, 11 pairs, such as B10 cone to B14 socket). |
| Adapters Cone Screw Thread | 2 | A ground cone joined to a GL14, GL18 or GL24 screw thread, and a swan-neck adapter with a GL14 side thread. |
| Adapters - Cone Socket with T Connection | 1 | An in-line cone and socket with a T branch on the side, in nine pairs from B14/B14 to B29/B29. |
| Adapters with Stopcock | 3 | A stopcock between a cone or socket and a rubber tubing outlet, straight or bent, in B14 to B29. |
| Tubing and Delivery Adapters | 2 | Listed directly in this range: a socket to rubber tubing adapter and a straight delivery adapter. |
Compare Laboratory Glassware Adapters by Joint Size
Each table below covers one sub-range. Joint sizes are B sizes as the product pages give them. A pair such as B24/B19 means a B24 cone with B19 sockets, except where a table says otherwise.
Adapters Multiple (3)
| Adapter | Necks | Pairs made | Cone / socket pairs |
|---|---|---|---|
| Adapters - Multiple, Two Necks | Two | 7 | B10/B10, B14/B14, B19/B19, B24/B19, B34/B19, B24/B24, B29/B29 |
| Adapters - Multiple, One Parallel and One 45 Degree Neck | One parallel, one at 45° | 5 | B19/B19, B24/B19, B34/B19, B24/B24, B29/B29 |
| Adapters - Multiple, Two Parallel and One 45 Degree Neck | Two parallel, one at 45° | 2 | B24/B19, B29/B19 |
Adapters Cone (2)
| Adapter | Tubing connection | Cone sizes |
|---|---|---|
| Adapters - Cone and Rubber Tubing Right Angled Connection | At a right angle to the cone | B10, B14, B19, B24, B29, B34 |
| Adapters - Cone and Rubber Tubing Straight Connection | In line with the cone | B10, B14, B19, B24 |
Adapters Vertical (2)
| Adapter | Pattern | Cone | Socket |
|---|---|---|---|
| Adapters - Vertical, Sloping | Sloping | B19 | B19 |
| Adapters - Vertical, Delivery | Delivery | B19 | B19 |
Adapters Receiver (3)
| Adapter | Type | Cone / socket | Vacuum or flask detail |
|---|---|---|---|
| Adapters - Receiver Intermediate Perkin All Glass Taps | Perkin receiver with all-glass taps | B14/B14, B19/B19, B24/B19, B24/B24 | Receiver changed without breaking the vacuum |
| Adapters - Receiver Vacuum to take 4 x 100 ml flasks | Vacuum receiver for four flasks | B14/B19 | Takes 4 x 100 ml flasks; side tube for the vacuum line |
| Adapters - Receiver, Vertical with Vacuum Connection | Vertical receiver | B14/B19, B24/B19 | Side tube for the vacuum line |
Reduction and Expansion Adapters (2)
| Adapter | Direction | Pairs made | Cones | Sockets |
|---|---|---|---|---|
| Expansion Adapters | Steps up: cone smaller than socket | 11 | B10 to B29 | B14 to B40 |
| Reduction Adapters | Steps down: cone larger than socket | 19 | B14 to B55 | B10 to B34 |
Adapters Cone Screw Thread (2)
| Adapter | Thread | Through bore | Ground joints |
|---|---|---|---|
| Adapters - Cone and Screw Thread | GL14, GL18 or GL24 | Bore 6.0–7.0 mm (GL14), 7.0–8.5 mm (GL18), 10.5–11.5 mm (GL24) | Cones B14 to B34 (GL14), B14 to B29 (GL18), B19 to B34 (GL24) |
| Adapters - Swan Neck, Thread Size GL14 | GL14 | Not listed | Socket: B14, cone: B14; socket: B19, cone: B19; socket: B19, cone: B24; socket: B24, cone: B24 (side thread GL14) |
Adapters - Cone Socket with T Connection (1)
| Adapter | Side branch | Pairs made | Socket and cones |
|---|---|---|---|
| Adapters - Cone and Socket with T Connection | T connection | 9 | Socket B14: cones B14, B19, B24. Socket B19: cones B19, B24, B29, B34. Socket B24: cone B24. Socket B29: cone B29. |
Adapters with Stopcock (3)
| Adapter | Joint end | Tubing outlet | Joint sizes |
|---|---|---|---|
| Adapters - Stopcock Cone and Rubber Tubing Straight Connection | Cone | Straight | B14, B19, B24, B29 |
| Adapters - Stopcock, Cone and Rubber Tubing, Bent Connection | Cone | Bent | B14, B19, B24, B29 |
| Adapters - Stopcock, Socket and Rubber Tubing, Straight Connection | Socket | Straight | B14, B19, B24, B29 |
Tubing and Delivery Adapters (2)
| Adapter | Joint end | Other end | Socket sizes |
|---|---|---|---|
| Adapters - Socket and Rubber Tubing, Straight Connection | Socket | Rubber tubing, straight | B19, B24, B29 |
| Adapters - Straight Delivery | Socket | Straight delivery end | B14, B19, B24, B29, B34 |
How to Choose Laboratory Glassware Adapters
- Measure the joints first. Note the B size of every neck, condenser outlet and fitting the adapter must meet. A cone seats only in a socket of the same B size.
- Cone end or socket end. A cone fits into a socket, such as a flask neck. A socket fits over a cone, such as a condenser outlet. For tubing, the cone and cone stopcock adapters go into sockets, while the socket to tubing adapter and the socket stopcock adapter go over cones.
- Joints that do not match. Reduction Adapters seat a larger cone in a wide neck and offer a smaller socket, in 19 pairs. Expansion Adapters do the opposite, in 11 pairs from a B10 cone to B14 socket up to a B29 cone to B40 socket.
- More fittings on one neck. The two-neck adapter is made in seven pairs from B10/B10 to B29/B29. The three-neck version gives B19 sockets on a B24 or B29 cone.
- One receiver, several fractions or vacuum. The straight and vertical delivery adapters pass distillate to one flask. The vertical receiver has a vacuum connection. The four-flask receiver collects up to four fractions, and the Perkin receiver lets the receiver be changed under vacuum.
- Taps, branches and threads. Choose a stopcock adapter to open or shut a tubing line at the joint, the T connection adapter for a side branch, and a cone and screw thread adapter where a threaded fitting must join a ground joint.
Tasks Covered by Laboratory Glassware Adapters
Who Uses Laboratory Glassware Adapters?
Chemistry laboratories of schools, colleges, universities and research and quality control labs use them wherever jointed glassware is assembled for distillation, reflux, vacuum work or gas and water lines. Glassware stores keep them to join pieces whose joint sizes differ.
Ordering, Minimum Quantity and Dispatch
| Point | Detail |
|---|---|
| Minimum order quantity | 50 units of each adapter, as shown on its product page |
| Pack quantity | Each adapter is sold individually |
| Dispatch time | Usually 3–5 working days |
| How to enquire | Use Add To Cart on a product page, or send the adapter names, joint sizes and quantities through the contact page |
| Tenders and OEM supply | Send the schedule through the tender enquiry page |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Related Ranges in Lab Glassware
Laboratory Glassware Adapters is one of 22 subcategories of the Lab Glassware range. These neighbouring ranges hold the jointed pieces the adapters connect.
| Range | How it relates |
|---|---|
| Bends | Plain, socket to cone, recovery and receiver bends, including a multi-connection pig receiver and bends with a vacuum connection or a vent. |
| Condensers | Air, Allihn, Graham coil, Davies double surface, jacketed coil and Liebig condensers, the pieces that delivery and receiver adapters follow in a distillation. |
| Distillation | Vigreux columns and distillation heads, including Claisen, splash and steam distillation heads. |
| Flasks | Round-bottom flasks with one, two or three necks, pear-shaped, Kjeldahl, iodine, filter and rotary evaporator flasks. |
| Screwthreads, Discs and Joints | Single cones and sockets, spherical, screwthread and flat flange joints, sintered discs and plastic joint clips. |
| Screw Caps, Stoppers and Stopcocks | Caps, PTFE washers, rubber rings, stoppers, and stopcocks with glass or PTFE keys in straight, T bore, double oblique and high vacuum forms. |
| Test Tubes and Thermometer Pockets | Test tubes, angled drying tubes, air inlet tubes with a cone, thermometer pockets and thermometers with a cone. |
Frequently Asked Questions
How do I find the B size a joint needs?
The number in a B size is roughly the diameter, in millimetres, of the wide end of the ground zone. Measure across the wide end of the cone, or across the mouth of the socket, with a vernier caliper. Then order an adapter with the same B number on that end.
Can these adapters join glassware made to other joint standards?
B joints have a 1 in 10 taper. Joints of the same diameter and the same taper can be fitted together even when their ground lengths differ, although only the overlapping length seals. Joints with a different taper or a different diameter should not be forced together.
How should cone and socket sizes be written on an order?
Name the adapter, then write the cone size and the socket size in words, for example "B24 cone, B19 socket". The reduction, expansion and swan-neck GL14 pages write each joint in words, such as Socket: B19; cone: B24 on the swan-neck adapter, so read the words, not the size order.
Why does a ground joint seize, and how is it prevented?
A joint can stick when liquid or solid creeps into it and dries, and strong alkali can etch the glass and lock the faces together. Keep the ground faces clean and dry, grease them lightly where the method allows, and take the joints apart soon after use.
Why must the side tube of a receiver adapter stay open in a simple distillation?
At normal pressure the side tube is the vent of the apparatus. If it is closed, the heated set-up becomes a closed system and the pressure can force a joint open or crack the glass. Connect the side tube to a vacuum line only for a vacuum distillation.
Do hanging joints need clips?
Yes. A flask hanging below a receiver or delivery adapter should be held by a joint clip and supported by a clamp, or it can slip off and break. Plastic clips should not be fitted on the hot joint next to the heated flask, where they can soften.
Request a Quote
Name each adapter with its cone size, socket size and quantity, for example 50 Reduction Adapters with a B24 cone and a B19 socket. Then send the list from the contact page.
Adapters - Socket and Rubber Tubing, Straight Connection
Product Code : EL-LGA-1569
Adapters - Socket and Rubber Tubing, Straight Connection connect a cone-ended piece to rubber tubing and are made in socket sizes B19, B24 and B29.
View Details
Adapters - Straight Delivery
Product Code : EL-LGA-1573
The Straight Delivery adapter has a B14, B19, B24, B29 or B34 socket and passes liquid straight through to its delivery end, typically from a condenser into a receiver.
View Details