• +91-85699-09696

categories

Test Tubes and Thermometer Pockets Manufacturer, Suppliers and Exporter in India

Jlabexport is a leading Test Tubes and Thermometer Pockets Manufacturer,and suppliers in India, United States, Indonesia, Brazil, Bangladesh, Mexico, Japan, Egypt, Philippines, Democratic Republic of the Congo, Vietnam, Iran, Turkey, Tanzania, United Kingdom, France, South Africa, Italy, Kenya, Colombia, Sudan, Uganda, South Korea, Argentina, Afghanistan, Yemen, Angola, Morocco, Poland, Uzbekistan, Mozambique, Malaysia, Ghana, Saudi Arabia, Peru, Madagascar, Côte d’Ivoire, Cameroon, Niger, Venezuela, Australia, Syria, Mali, Burkina Faso, Sri Lanka, Malawi, Zambia, Chad, Kazakhstan, Somalia, Chile, Senegal, Ecuador, Cambodia, Zimbabwe, Guinea, Benin, Rwanda, Burundi, Bolivia, South Sudan, Tunisia, Haiti, Belgium, Dominican Republic, Jordan, United Arab Emirates, Honduras, Tajikistan, Papua New Guinea, Portugal, Togo, Sierra Leone, Belarus, Laos, Turkmenistan, Libya, Kyrgyzstan, Nicaragua, Paraguay, Bulgaria, Serbia, Republic of the Congo, Lebanon, Liberia, Central African Republic, Palestine, Oman, Mauritania, New Zealand, Costa Rica, Kuwait, Panama, Croatia, Georgia, Eritrea, Mongolia, Uruguay, Qatar, Namibia, Bosnia and Herzegovina, Moldova, Armenia, Gambia, Jamaica, Lithuania, Albania, Gabon, Botswana, Lesotho, Guinea-Bissau, Slovenia, Equatorial Guinea, Latvia, North Macedonia, Bahrain, Trinidad and Tobago, Timor-Leste, Cyprus, Estonia, Eswatini, Mauritius, Djibouti, Fiji, Comoros, Solomon Islands, Guyana, Bhutan, Luxembourg, Suriname, Montenegro, Malta, Maldives, Cabo Verde, Brunei, Belize, Bahamas, Iceland, Vanuatu, Barbados, São Tomé and Príncipe, Samoa, Saint Lucia, Kiribati, Seychelles, Grenada, Saint Vincent and the Grenadines, Antigua and Barbuda.

Last updated: 14 November 2026

What Are Jointed Test Tubes, Air Inlets and Thermometer Pockets?

This range holds small jointed pieces that seat in the sockets of flasks, condensers and distillation heads, together with test tubes that carry a joint socket of their own. Chemistry teaching and research laboratories use them to close or connect apparatus, keep moisture out, feed air or gas into a liquid and measure temperature. The six items are socketed test tubes from 2 ml to 195 ml, angled drying tubes, bent and straight air inlet tubes, thermometer pockets and thermometers with a B14 cone. JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India, makes all six.

Request a quotation  |  Compare the items  |  See the tasks covered

Which Items Are in the Test Tubes and Thermometer Pockets Range?

GroupItemsWhat it covers
Socketed Test Tubes1Test tubes from 2 ml to 195 ml with a B10, B14, B19, B24 or B34 socket at the mouth.
Drying Tubes and Air Inlets3Angled drying tubes, and bent and straight air inlet tubes, on cones from B10 to B29.
Thermometer Pockets and Thermometers2Pockets with a B14 or B19 cone, and thermometers with a B14 cone in four ranges up to 400 °C.

Compare Jointed Tubes and Thermometer Fittings by Joint Size

Each table sets the items of one group side by side, with the sizes given on each product page. Joint sizes use the B designation, so a B14 cone fits a B14 socket.

Socketed Test Tubes (1)

Test tubeSocket sizesCapacitiesTube diameters
Laboratory Test TubesB10, B14, B19, B24, B342 ml to 195 ml14 mm to 41 mm

The socket follows the capacity. The 2 ml and 5 ml tubes have a B10 socket, and the 11, 15 and 19 ml tubes a B14 socket. A second 19 ml tube and the 31 ml tube have B19, the 54 ml and 75 ml tubes B24, and the 195 ml tube B34.

Drying Tubes and Air Inlets (3)

ItemFormStem lengthCone sizes
Tubes, Drying, AngledAngled drying tubeNot listedB10, B14, B19, B24, B29
Tubes And Air Inlets, Bent With ConeBent inlet tube150 mmB14, B19, B24
Tubes and Air Inlets, Straight With ConeStraight inlet tube100 mmB10, B14, B19, B24, B29

Thermometer Pockets and Thermometers (2)

ItemVersionConeStem lengthTemperature range
Thermometer PocketsShort pocketB1445 mmTakes a separate thermometer
Thermometer PocketsLong pocketB19200 mmTakes a separate thermometer
Thermometers With ConeFour rangesB14Not listed0–110, 0–200, 0–300 or 0–400 °C

How to Choose Jointed Tubes and Thermometer Fittings

  • Start from the joint on your apparatus: B14 runs through every group: a B14 test tube socket, B14 drying and inlet tubes, the short B14 pocket and all four cone thermometers.
  • Test tube capacity: Choose the capacity first; the socket comes with it, from B10 on the smallest tubes to B34 on the 195 ml tube.
  • Drying tube or air inlet: A drying tube lets the apparatus breathe while its packing holds back moisture. An inlet tube carries air or gas down into the vessel.
  • Bent or straight inlet: The bent tube has a 150 mm stem and turns the supply end to the side, clear of the neck. The straight tube has a 100 mm stem and five cone sizes.
  • Pocket or cone thermometer: A pocket keeps the thermometer out of the contents and takes a thermometer of your choice. A cone thermometer sits straight in a B14 socket; pick the range by the highest temperature reached.
  • Depth of reading: The 45 mm pocket suits shallow insertion through a B14 neck; the 200 mm pocket reaches deeper into a larger flask or reactor.

Tasks Covered by the Test Tubes and Thermometer Pockets Range

TaskApparatus
Small-scale reactions and storage in a test tube closed or connected by a cone fittingLaboratory Test Tubes
Keeping moist air out of a reflux or reaction set-upTubes, Drying, Angled
Bubbling air or gas through a liquid in a flaskTubes and Air Inlets, Straight With Cone, Tubes And Air Inlets, Bent With Cone
Feeding gas from a side line clear of the flask neckTubes And Air Inlets, Bent With Cone
Measuring the temperature of a reaction mixture in a flask or reactorThermometer Pockets
Reading the vapour temperature in a distillation head or adapterThermometers With Cone

Who Uses Jointed Test Tubes and Thermometer Pockets?

Organic and inorganic chemistry teaching labs, research labs and quality control labs use these pieces with jointed glassware. Students meet them in reflux, distillation and gas-handling practicals.

Ordering, Minimum Quantity and Dispatch

PointDetail
Minimum order quantityFrom 15 units (Thermometers With Cone) to 100 units (Laboratory Test Tubes); 50 units for the drying tubes, inlet tubes and pockets. Each product page shows its own.
Dispatch timeUsually 3–5 working days; 4–6 working days for the cone thermometers
Pack quantityEach (sold individually)
How to enquireChoose the size and press Add To Cart on a product page, or send the item names, joint sizes and quantities through the contact page
Tenders and OEM supplySee laboratory tenders
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab), Ambala, India

Related Ranges in Lab Glassware

Test Tubes and Thermometer Pockets is part of Lab Glassware. These ranges hold the jointed ware that the tubes, inlets and pockets fit into.

RangeHow it relates
Screwthreads, Discs and JointsSingle cones and sockets, cones with tip and spherical joints for building jointed pieces
DistillationDistillation heads, including Claisen and splash heads, and Vigreux columns
CondensersLiebig, Allihn, air and coil condensers that a drying tube can top
FlasksRound bottom and pear shaped flasks with two or three necks for inlets and pockets
StirrersOverhead stirrer shafts, a B19 stirrer gland and stirrer guides
Specimen Tubes and VialsSpecimen tubes with push-in caps and neutral glass vials for plain storage

Frequently Asked Questions

What goes inside a drying tube, and how is it packed?
Put a loose plug of cotton wool at the base, fill the tube with a granular drying agent such as anhydrous calcium chloride, and close it with a second plug. Keep the packing loose enough for gas to pass, and renew the agent once it cakes.

Where does a drying tube go on a reflux set-up?
Seat it in the socket at the top of the condenser, so air drawn in as the flask cools passes through the drying agent first. Turn the angled end down or to the side so dust and drips do not fall into the tube.

Can a drying tube be used to seal a heated reaction?
No. A drying tube is not a seal, and gas must pass through it freely. A tightly packed or caked tube can let a heated or gas-forming reaction build pressure. Check that air flows through it before heating starts.

Why put a little liquid in a thermometer pocket?
Air in the pocket insulates the bulb, so the reading lags behind the contents. A small amount of a heat-transfer liquid that suits the working temperature, such as silicone oil, fills the gap so the reading follows the flask.

Why must ground joints be matched and kept tight?
A cone seals only in a socket of the same size, such as B14 in B14. A loose or mismatched joint leaks vapour and can let the piece drop out. Use a thin film of grease where the joint must hold gas, and wipe off any excess.

Request a Quote

Name each item with its joint size, capacity, stem or temperature range, and the quantity of each, then send the list through the contact page or with Add To Cart on the product pages.

Laboratory Test Tubes

Laboratory Test Tubes

Product Code : EL-TTATP-1694

Laboratory Test Tubes are made with a standard joint socket at the mouth and come in capacities from 2 ml to 195 ml, with sockets from B10 to B34.

View Details
Tubes, Drying, Angled

Tubes, Drying, Angled

Product Code : EL-TTATP-1695

Tubes, Drying, Angled are angled drying tubes with a standard cone, offered in B10, B14, B19, B24 and B29 cone sizes for jointed apparatus.

View Details
Tubes And Air Inlets, Bent With Cone

Tubes And Air Inlets, Bent With Cone

Product Code : EL-TTATP-1696

Tubes And Air Inlets, Bent With Cone are bent inlet tubes with a 150 mm stem, made with a B14, B19 or B24 cone to fit a matching socket.

View Details
Tubes and Air Inlets, Straight With Cone

Tubes and Air Inlets, Straight With Cone

Product Code : EL-TTATP-1697

Tubes and Air Inlets, Straight With Cone are straight inlet tubes with a 100 mm stem, made with a B10, B14, B19, B24 or B29 cone.

View Details
Thermometer Pockets

Thermometer Pockets

Product Code : EL-TTATP-1698

Thermometer Pockets hold a thermometer inside a jointed vessel and are made with a 45 mm stem and B14 cone or a 200 mm stem and B19 cone.

View Details
Thermometers With Cone

Thermometers With Cone

Product Code : EL-TTATP-1699

Thermometers With Cone fit straight into a B14 socket and are offered in 0-110, 0-200, 0-300 and 0-400 C temperature ranges.

View Details

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us