Laboratory condensers are glassware components used to cool vapour and convert it into liquid during distillation, reflux and solvent-recovery procedures. This category is intended for schools, universities, TVET institutions, research laboratories and industrial buyers selecting condensers by design, cooling surface area, effective length, overall length and laboratory joint configuration.

Jlab Export is a Manufacturer & Exporter of air, Allihn, Graham coil, double-surface Davies, jacketed-coil and Liebig condensers from Ambala, India. The category contains six listed products, with product codes from JL-C-1596 to JL-C-1601. Confirmed effective lengths range from 60 mm to 550 mm, while listed socket and cone options extend from B10 to B50, depending on the condenser design. Some configurations are listed without a socket, and selected Allihn and Graham models can be ordered with threaded connections instead of water connections.

Jlab Export states that it serves markets across Asia, Africa, Europe, North America, South America and Oceania.

What products are included in the Condensers category?

The Condensers category contains six laboratory condenser designs: air, Allihn, Graham coil, double-surface Davies, jacketed coil and Liebig. Each product has a separate JL-C code and a specification table covering some combination of cooling surface area, effective length, overall length, socket size, cone size or catalogue item number.

The listed products are:

  • Condensers Air — JL-C-1596
  • Condensers Allihn — JL-C-1597
  • Condensers Coil Graham — JL-C-1598
  • Condensers Double Surface Davies — JL-C-1599
  • Condensers Jacketed Coil — JL-C-1600
  • Condensers, Liebig — JL-C-1601

The individual listings do not consistently state glass composition, water-connection diameter, wall thickness, hose requirements or operating limits. Specifications are available on request.

How do you choose a laboratory condenser?

Choose a laboratory condenser by matching the design, effective cooling length, surface area and both joint connections to the intended apparatus. Buyers should also confirm whether the model requires water connections, threaded connections or no socket at one end, because the available configurations vary substantially across the six products.

Use this selection sequence:

  1. Identify the required condenser design.
  2. Select the listed effective length.
  3. Confirm cooling surface area where stated.
  4. Match the socket size.
  5. Match the cone size.
  6. Check the overall length against the apparatus.
  7. Confirm water or threaded connection requirements.
  8. Request missing construction and operating specifications.

A request based only on length is insufficient because multiple condensers may share the same effective length while differing in surface area, overall length and joints.

Which air condenser configurations are listed?

Air Condenser JL-C-1596 is listed in seven configurations with surface areas from 30 cm² to 500 cm², effective lengths from 100 mm to 550 mm and overall lengths from 120 mm to 570 mm. Socket and cone options range from B10 to B29.

Surface area

Effective length

Overall length

Socket

Cone

30 cm²

100 mm

120 mm

B10

B10

100 cm²

200 mm

225 mm

B14

B14

100 cm²

150 mm

170 mm

B19

B19

200 cm²

300 mm

320 mm

B19

B19

400 cm²

400 mm

430 mm

B19

B24

400 cm²

550 mm

570 mm

B24

B24

500 cm²

550 mm

570 mm

B29

B29

Buyers should state all five fields because the same surface area or effective length may appear in more than one configuration.

Which Allihn condenser sizes are available?

Allihn Condenser JL-C-1597 is listed mainly with a 200 mm effective length, with cone sizes from B19 to B50. One jointed configuration has a 300 mm effective length with B24 socket and B24 cone. The page also states that threaded connections can replace water connections by adding “/T” to the code number.

Surface area

Effective length

Overall length

Socket

Cone

130 cm²

200 mm

285 mm

Not listed

B19

130 cm²

200 mm

285 mm

Not listed

B24

130 cm²

200 mm

295 mm

Not listed

B29

130 cm²

200 mm

310 mm

Not listed

B34

130 cm²

200 mm

310 mm

Not listed

B40

150 cm²

200 mm

310 mm

Not listed

B50

180 cm²

300 mm

400 mm

B24

B24

The meaning of the missing socket entries should be confirmed before quotation or publication.

What Graham coil condenser options are listed?

Graham Coil Condenser JL-C-1598 is offered with effective lengths of 150 mm, 200 mm and 300 mm. Listed surface areas range from 230 cm² to 450 cm², and available cone sizes extend from B19 to B50. Selected versions have matching sockets, while others show no socket.

Surface area

Effective length

Overall length

Socket

Cone

230 cm²

150 mm

265 mm

B19

B19

230 cm²

150 mm

265 mm

B24

B24

450 cm²

300 mm

420 mm

B19

B19

450 cm²

300 mm

420 mm

B24

B24

450 cm²

300 mm

420 mm

B29

B29

230 cm²

150 mm

260 mm

Not listed

B29

230 cm²

150 mm

260 mm

Not listed

B34

350 cm²

200 mm

300 mm

Not listed

B40

400 cm²

200 mm

315 mm

Not listed

B45

400 cm²

200 mm

315 mm

Not listed

B50

The page also states that threaded connections are available instead of water connections by adding “/T” to the code number.

Which double-surface Davies condenser configurations are available?

Double-Surface Davies Condenser JL-C-1599 is listed with effective lengths of 150 mm or 200 mm and surface areas from 180 cm² to 300 cm². Most configurations have matching socket and cone sizes, while one 200 mm model lists no socket and a B24 cone.

Surface area

Effective length

Overall length

Socket

Cone

180 cm²

150 mm

240 mm

B14

B14

180 cm²

150 mm

250 mm

B19

B19

230 cm²

150 mm

250 mm

B24

B24

250 cm²

200 mm

300 mm

B19

B19

300 cm²

200 mm

300 mm

B24

B24

300 cm²

200 mm

315 mm

B29

B29

300 cm²

200 mm

290 mm

Not listed

B24

Buyers should verify whether the socket-free entry is an intentional cone-only version or an incomplete specification.

What jacketed-coil condenser sizes are listed?

Jacketed Coil Condenser JL-C-1600 is listed with a 430 cm² surface area and 150 mm effective length across all four configurations. Three options have matching B19, B24 or B29 socket-and-cone joints, while the fourth lists no socket and a B34 cone.

Surface area

Effective length

Overall length

Socket

Cone

430 cm²

150 mm

320 mm

B19

B19

430 cm²

150 mm

320 mm

B24

B24

430 cm²

150 mm

320 mm

B29

B29

430 cm²

150 mm

300 mm

Not listed

B34

The product page does not provide coil diameter, jacket diameter, water-connection size or cooling-fluid requirements. These details should be requested where apparatus compatibility or performance must be evaluated.

Which Liebig condenser models are available?

Liebig Condenser JL-C-1601 is listed in seven catalogue configurations with effective lengths from 60 mm to 400 mm. Socket and cone sizes are matched within each entry and range from B10 to B29.

Catalogue item

Effective length

Socket

Cone

CL60/00

60 mm

B10

B10

CL15/11

150 mm

B14

B14

CL20/22

200 mm

B19

B19

CL20/33

200 mm

B24

B24

CL40/22

400 mm

B19

B19

CL40/33

400 mm

B24

B24

CL40/44

400 mm

B29

B29

The product table also contains an “Each” column with unexplained numerical values. These values should not be published as prices or specifications until their meaning and currency are confirmed.

How should schools, universities and TVET institutions select condensers?

Educational institutions should select condensers from the practical schedule or apparatus list, then confirm design, effective length and joint compatibility. A school, university or TVET buyer should not substitute one condenser type for another solely because the length or joint size appears similar.

The enquiry should include:

  • Product name and JL-C code
  • Required condenser type
  • Effective length
  • Overall length
  • Surface area, where specified
  • Socket size
  • Cone size
  • Water or threaded connection requirement
  • Number required per laboratory
  • Packing and documentation requirements

Where the BOQ states only “laboratory condenser,” request a technical compliance statement identifying the exact product proposed.

What should research and industrial buyers verify?

Research and industrial buyers should verify the condensers material, cooling-path dimensions, joint tolerances and operating limitations. The individual listings provide dimensional combinations but do not consistently establish glass grade, water-flow requirements, thermal-shock resistance or pressure and vacuum suitability.

Request confirmation of:

  • Glass material and grade
  • Inner and outer tube diameters
  • Coil or bulb dimensions
  • Water-connection diameter and type
  • Recommended cooling-fluid direction
  • Joint tolerances
  • Wall thickness
  • Temperature limitations
  • Chemical compatibility
  • Pressure or vacuum suitability
  • Included tubing or accessories

Product-specific technical documents should identify the exact JL-C code and configuration.

What should tender and bulk buyers include in an enquiry?

Tender and bulk buyers should submit the JL-C product code, complete dimensional combination, quantity, destination and documentation requirements. Jlab Export states that applicable institutional orders can include line-by-line BOQ quotations, technical datasheets, compliance documentation and export-grade packing.

Include:

  • Tender or project reference
  • Product name and code
  • Surface area
  • Effective and overall lengths
  • Socket and cone sizes
  • Water or threaded connection
  • Material specification
  • Quantity
  • Inspection requirements
  • Packing and carton markings
  • Delivery country
  • Required certificates or declarations
  • Submission deadline

Any deviation from the BOQ should be identified in the technical quotation before approval.

Condenser Product Types

Type

Key listed feature

Typical use

Air Condenser

100–550 mm effective length; 30–500 cm² surface area

Apparatus schedules specifying an air-cooled condenser

Allihn Condenser

Mostly 200 mm effective length; B19–B50 cone options

Distillation or reflux assemblies specifying an Allihn design

Graham Coil Condenser

150–300 mm effective length; 230–450 cm² surface area

Apparatus requiring the listed coil-condenser configuration

Double-Surface Davies Condenser

150 or 200 mm effective length

Assemblies specifying a double-surface Davies design

Jacketed Coil Condenser

150 mm effective length; 430 cm² surface area

Assemblies specifying the listed jacketed-coil configuration

Liebig Condenser

60–400 mm effective length; catalogue items CL60/00 to CL40/44

Apparatus specifying a straight Liebig condenser

The table reflects only the configurations and dimensions stated on the category and individual product pages.

Condenser Selection Criteria

Criterion

What to check

Condenser design

Air, Allihn, Graham coil, Davies, jacketed coil or Liebig

Product code

Confirm JL-C-1596 to JL-C-1601

Surface area

Match the stated cm² value where provided

Effective length

Select the listed working length

Overall length

Confirm available space in the apparatus

Socket size

Match the stated B-series socket

Cone size

Match the receiving apparatus joint

Missing socket

Verify entries displayed with a dash

Cooling connection

Confirm water connections or threaded alternatives

Glass material

Request the glass type and grade

Tube dimensions

Request inner, outer, coil, bulb and jacket dimensions

Operating conditions

Confirm chemical, thermal, pressure and vacuum suitability

Quantity

State units required per laboratory or project

Packing

Confirm individual and export packing

Documentation

State datasheet, drawing, inspection and certificate requirements

Jlab Export Links

Frequently Asked Questions

How many products are listed in the Condensers category?

The category contains six products with codes from JL-C-1596 to JL-C-1601: Air, Allihn, Graham Coil, Double Surface Davies, Jacketed Coil and Liebig condensers.

What effective lengths are available for air condensers?

Air Condenser JL-C-1596 is listed with effective lengths of 100, 150, 200, 300, 400 and 550 mm. Some lengths appear with different surface areas or joints, so the complete configuration must be specified.

Can Allihn condensers be supplied with threaded connections?

Yes. The Allihn product page states that threaded connections are available instead of water connections at no extra cost and instructs buyers to add “/T” to the code number. The required thread specification should still be confirmed before ordering.

What is the largest surface area listed for a Graham condenser?

The largest surface area shown for Graham Coil Condenser JL-C-1598 is 450 cm², paired with a 300 mm effective length and 420 mm overall length. B19, B24 and B29 matching socket-and-cone options are listed for this configuration.

What effective length is listed for jacketed-coil condensers?

All four Jacketed Coil Condenser JL-C-1600 configurations show an effective length of 150 mm and a surface area of 430 cm². Their overall lengths and joint combinations vary.

What is the shortest Liebig condenser listed?

The shortest listed Liebig model is catalogue item CL60/00, with a 60 mm effective length, B10 socket and B10 cone.

Are glass material and operating limits confirmed online?

No. The individual listings do not consistently state glass composition, wall thickness, water-connection dimensions, chemical compatibility, temperature limits, or pressure and vacuum suitability. These specifications should be requested for the selected product code.

Are the stated certifications product-specific?

Product-specific certificates are not supplied on the six individual listings. The category and About pages contain manufacturer-stated certification and standards claims, but their validity, scope and applicability must be verified before publication or procurement.

Request a Quote for Laboratory Condensers

Request current configurations, effective and overall lengths, surface areas, joint sizes, connection details, documentation, quantity-based pricing and export-packing information.

Request a Quote

Request Catalogue

Condensers Air

Condensers Air

Product Code : JL-C-1596

View Details
Condensers Allihn

Condensers Allihn

Product Code : JL-C-1597

View Details
Condensers Coil Graham

Condensers Coil Graham

Product Code : JL-C-1598

View Details
Condensers Jacketed Coil

Condensers Jacketed Coil

Product Code : JL-C-1600

View Details
Condensers, Liebig

Condensers, Liebig

Product Code : JL-C-1601

View Details

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us