• +91-85699-09696

Condensers Coil Graham Manufacturer,Supplier and Exporter in India

Condensers Coil Graham

Product Code : EL-C-1598
Jlab Export is a leading Condensers Coil Graham Manufacturer,and suppliers in India

In a Graham condenser the vapour passes through a glass coil that runs the length of a water jacket. The spiral packs a large cooling surface into a short body: 230 sq cm on the 150 mm models and 450 sq cm on the 300 mm models. Ten versions are made, with a socket and cone or with a single cone from B29 to B50.

Sizes and Cooling Surfaces

TypeGraham coil condenser, vapour in the coil, water in the jacket
150 mm, socket and coneB19 or B24, 230 sq cm, 265 mm overall
300 mm, socket and coneB19, B24 or B29, 450 sq cm, 420 mm overall
150 mm, cone onlyB29 or B34, 230 sq cm, 260 mm overall
200 mm, cone onlyB40 (350 sq cm, 300 mm overall), B45 or B50 (400 sq cm, 315 mm overall)
Water connectionsStandard or screw-thread
Minimum order quantity50 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Lab Work with a Vertical Coil Condenser

Food and agriculture students measure the protein in grain by the Kjeldahl method. After digestion, the liquid in a Kjeldahl Flasks JLab is made alkaline and the ammonia is distilled through the upright coil into boric acid. A delivery adapter, the Adapters - Vertical, Delivery, fits the lower B19 cone and leads the distillate below the surface of the acid before the titration. At the end of the distillation, the receiver is lowered so the tip clears the acid before the heat is turned off, which stops suck-back.

In an organic lab the condenser recovers a volatile solvent such as ethanol after an extraction. The condensate runs down the turns of the coil and drips into a Flasks, Conical Erlenmeyer, Standard Wall JLab fitted below. Students then compare the volume recovered with the volume they started with.

Frequently Asked Questions

Why must a Graham condenser be mounted upright?
Condensate has to run down the turns of the coil by gravity. When the condenser is tilted, parts of the spiral slope uphill and liquid lies in them, which slows the flow and can block the vapour path. Clamp it vertical, with the vapour entering at the top.

Is it a good choice for heating under reflux?
Only for gentle boiling. Under reflux the condensate must fall back down the same narrow coil that the vapour rises through, so the coil floods at higher boil-up rates. For vigorous reflux, the bulbed Condensers Allihn copes better.

How is a Graham condenser different from a coil condenser?
In a Graham condenser the vapour passes through the glass coil and the cooling water fills the jacket around it. In a coil condenser the paths are swapped, with water inside the coil and vapour around it. The names sound alike, so check which pattern a method asks for.

How do I clean the inside of the coil?
A brush cannot follow the turns, so rinse the coil instead. Run a solvent that dissolves the residue through it, then water, and stand it upright to drain. Do not let solids or tarry residue dry inside, because the narrow bore clogs easily.

Other Water-Cooled and Air Condensers

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 14 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us