Condensers Jacketed Coil Manufacturer,Supplier and Exporter in India
Product Code : EL-C-1600
Jlab Export is a leading Condensers Jacketed Coil Manufacturer,and suppliers in India
This condenser puts two cold surfaces round the vapour: a water-cooled glass coil inside and a water jacket outside. Vapour condenses in the space between them, on 430 sq cm of cooling glass in a 150 mm effective cooled length. Three versions have a matching socket and cone from B19 to B29, and one has a B34 cone only.
Specifications
| Type | Jacketed coil condenser, water-cooled coil and jacket |
| Effective cooled length | 150 mm, all models |
| Cooling surface | 430 sq cm |
| Overall length | 320 mm (B19, B24 and B29 models), 300 mm (B34 model) |
| Joints | B19, B24 or B29 socket and matching cone, or B34 cone only |
| Minimum order quantity | 50 units |
| Dispatch time | Usually 3–5 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Practicals with Heavy Vapour Loads
Making soap is a classroom reflux practical. Students boil a vegetable oil with sodium hydroxide solution in a Flasks, Round Bottom, Two Necks, Angled Side Neck JLab, with the condenser in the centre neck. A Thermometers With Cone closes the side neck and reads the temperature inside the flask, and a Heating Mantle keeps it boiling steadily.
For oil extraction in the larger Extractors Soxhlet, the B34 cone-only model fits the B34 top socket of the extractor. Its coil and jacket take the steady stream of hot solvent vapour over a run of many cycles.
Frequently Asked Questions
Why is the coil surrounded by a water jacket?
In a plain coil condenser only the coil is cold, and the outer wall warms during a long run, so vapour can creep past it. Here the jacket is cooled as well. The outer wall stays cold, and the condenser gives 430 sq cm of cooling surface in a 150 mm effective cooled length.
Which jobs suit a jacketed coil condenser?
Jobs that send a lot of vapour up the condenser: fast reflux of a large charge, continuous extraction in a Soxhlet, or the recovery of a volatile solvent. The vapour moves through an open space around the coil rather than a narrow tube, so it does not choke as easily.
Which cone do I need for my flask or extractor?
Match the lower cone to the socket it goes into. The B19, B24 and B29 models also have a socket at the top, which can take a drying tube or an adapter. The B34 model has a cone only and suits wider necks and the larger extractors.
Other Laboratory Condensers
- Condensers Coil Graham (vapour inside the coil)
- Condensers Double Surface Davies
- Condensers Allihn
- Condensers, Liebig
For a quote, use Add To Cart or send us a message through the contact page.