Jlab Export is a leading Extractors Soxhlet Manufacturer,and suppliers in India
Solid samples are extracted in this glass body by repeated washing with fresh hot solvent. Vapour from the flask condenses above the sample, the chamber fills, and a siphon returns the solvent and what it has dissolved to the flask. Nine sizes run from 6 ml to 600 ml nominal capacity, and the 600 ml size has a 75 mm flat flange instead of a socket.
Sizes and Joints
| Type | Soxhlet extractor body with siphon |
| 6 ml | B19 socket, B14 cone |
| 20 ml | B24 socket, B19 cone |
| 40 ml | B29 socket, B24 cone |
| 60 ml | B34 socket, B24 or B34 cone |
| 100 ml | B34 socket and B34 cone, or B40 socket and B24 cone |
| 200 ml | B50 socket, B24 cone |
| 600 ml | 75 mm flat flange, B34 cone |
| Minimum order quantity | 50 units |
| Dispatch time | Usually 3–5 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Extraction Practicals with a Soxhlet
Measuring the fat in a food sample is the classic Soxhlet exercise. The extractor stands on a Flasks, Round Bottom, Short Neck JLab warmed by a Heating Mantle, with a Condensers Allihn in its top socket. After the run, the solvent is distilled off and the flask is weighed to find the fat taken out.
Botany and pharmacy students extract pigments or other plant compounds from dried, powdered leaves with ethanol. They then compare the extracts by thin-layer chromatography.
Frequently Asked Questions
Why will the extractor not siphon?
Usually the chamber is filling too slowly, or the extractor is not standing upright. Raise the heat a little so the condenser gives a steady drip, and check the body is clamped vertical. A light tap on the glass often starts a sluggish siphon.
Why is the yield lower than expected?
Too few siphon cycles is the usual cause, so the solvent sits on the sample instead of washing it through. Keep a steady boil so the chamber refills and empties regularly, and grind the sample finely so the solvent reaches all of it.
How is the solvent recovered after the run?
Once the last siphon has emptied, take the extractor off and distil most of the solvent from the flask through a still head and condenser. The extract stays behind, and clean recovered solvent can be used again.
Which solvent should be used?
One that dissolves what you want and little else, and boils low enough to drive off easily. Hexane or petroleum ether is usual for oils and fats, and ethanol for more polar plant compounds. Heat these solvents with a mantle or water bath, never a flame.
Which size do I need?
Choose the capacity for the amount of sample, then check the joints. The socket at the top takes the condenser, and the cone at the bottom fits the flask. Two capacities, 60 ml and 100 ml, come with a choice of joints.
Other Extraction Equipment
- Soxhlet Extraction Unit (heater unit with mantles)
- Soxhlet Extraction Apparatus (complete set)
- Condensers Jacketed Coil
For a quote, use Add To Cart or send us a message through the contact page.