A Soxhlet extractor recycles hot solvent through a thimble of sample. The vapour rises, condenses, drips onto the sample and siphons back to the flask, cycle after cycle. This multi-place unit heats three or six extractions at once. It is made with heating mantles, heaters, hot plates or baths, and every place has its own switch.

Specifications

BodyMild steel body and upright fittings, stove-finished, other parts chrome plated
Mantle typeHeating mantles, surface temperature up to 300 °C, individual on-off switches and pilot lamps
Mantle units3 mantles (600 W) or 6 mantles (1200 W)
Heater type3 or 6 heaters, individual on-off switches and indicators, one common energy regulator, without glass parts
Hot plate type3 or 6 hot plates
Bath type3 or 6 baths, single-wall or double-wall stainless steel chamber
OptionalEnergy regulator for all versions
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Extraction Practicals for Students

Food science and agriculture students find the oil content of seeds such as groundnut or mustard. They weigh the ground seed into a thimble, extract it with a suitable organic solvent and weigh the oil left in the flask once the solvent is recovered. Each place holds one of the Extractors Soxhlet, with a flask from the Flasks, Round Bottom, Short Neck JLab below and one of the Condensers Allihn above.

In pharmacognosy, students extract a powdered crude drug and compare the yield from different solvents or extraction times. With six places, a batch of students can run their extractions side by side and weigh the results on an Electronic Balance Analytical.

Frequently Asked Questions

How many siphon cycles does an extraction need?
It depends on the sample and the method. Fine, dry material extracts in fewer cycles than coarse or moist material. Most methods give a fixed time or cycle count, and a further short extraction that yields nothing more shows the work is complete.

Which heating type should I choose?
Heating mantles fit round-bottom flasks closely and reach surface temperatures up to 300 °C. The heater and hot plate types heat flasks from below, and the heater type has one common energy regulator. The bath type gives gentler, even heat for low-boiling solvents.

Does the unit include the glassware?
The heater type is supplied without glass parts. Order the extractors, round-bottom flasks and condensers to suit the sample size you work with, so that every place on the unit carries a matching set.

How should the thimble be packed?
Grind and dry the sample, weigh it into the thimble and plug the top loosely with cotton so particles do not wash over. Keep the sample below the top of the siphon tube, or part of it is never covered by solvent.

What mistakes do students make most often?
Overfilling the flask, packing the thimble too tightly, forgetting the condenser water and heating too hard are the usual faults. A slow, steady drip from the condenser gives regular siphon cycles and a fair result.