• +91-85699-09696

Thermometers With Cone Manufacturer,Supplier and Exporter in India

Thermometers With Cone

Product Code : EL-TTATP-1699
Jlab Export is a leading Thermometers With Cone Manufacturer,and suppliers in India

Each of these glass thermometers carries a B14 ground cone on its stem. It seats directly in a B14 socket on a distillation head, flask or adapter, with no rubber bung needed. Four scales are offered: 0–110, 0–200, 0–300 and 0–400 °C.

Ranges and Cone

Temperature ranges0–110 °C, 0–200 °C, 0–300 °C, 0–400 °C
Cone sizeB14 on every range
Minimum order quantity15 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Distillation Practicals with a Cone Thermometer

In a simple distillation, the thermometer sits in the B14 socket of Distillation Heads fitted to Flasks, Round Bottom, Short Neck JLab. The vapour then passes on into a Condensers, Liebig. Students note the steady temperature at which most of the liquid distils and compare it with the known boiling point.

For a fractional distillation of ethanol and water, college students fit it to the socket of Pear Shaped Flasks, Claisen, Vigreux JLab. They plot temperature against the volume collected. The 0–110 °C scale covers that run, and the higher ranges suit liquids that boil well above water.

Frequently Asked Questions

Where should the bulb sit during a distillation?
Level with the side arm of the still head, where the vapour turns into the condenser. A bulb set too high reads below the true boiling point, and one set too low can read above it.

Why can a reading differ from the value in a data book?
Part of the liquid column sits above the cone, outside the hot zone, so at high temperatures the reading can be a little off. Impurities in the sample, air pressure and a bulb at the wrong height also shift the observed boiling point.

What should I do if the liquid column has separated?
Do not use the thermometer until the column is joined, as the gap gives a false reading. Cooling the bulb slowly in ice often draws the liquid down into the bulb so the parts rejoin. Let it warm slowly afterwards.

Should the cone be greased?
Usually not. A clean, dry cone seats well in a B14 socket and lifts out easily. If the joint must stay sealed through long heating, use only a very thin film on the upper part of the cone. That keeps grease off the stem.

How should these thermometers be stored?
Upright in a rack such as the Thermometer Storage Rack, away from heat and knocks. Standing upright helps keep the liquid column joined, and the bulb, the thinnest part, is kept clear of the bench.

Other Thermometers and Fittings

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 14 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us