• +91-85699-09696

Distillation Heads Manufacturer,Supplier and Exporter in India

Distillation Heads

Product Code : EL-D-1604
Jlab Export is a leading Distillation Heads Manufacturer,and suppliers in India

A distillation head, also called a still head, joins the boiling flask to the condenser. Vapour rises through its body, passes the thermometer held in the top socket and turns down the side arm into the condenser. Six versions are made, with flask cones from B10 to B24 and side-arm cones for B10 to B24 condensers.

Specifications

TypeStill head with flask cone, side-arm cone and top socket
B10 flask coneB10 condenser cone, B10 socket
B14 flask coneB14 condenser cone, B14 socket
B19 flask coneB19 condenser cone, B14 or B19 socket
B24 flask coneB19 or B24 condenser cone, B14 socket
Minimum order quantity50 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Simple Distillation Practicals

College students purify an organic liquid such as cyclohexene, made by dehydrating cyclohexanol, by simple distillation. The head sits in a Flasks, Round Bottom, Short Neck JLab and carries a Thermometers With Cone in its top socket. Its side arm feeds a sloping Condensers, Liebig.

To check purity, students note the temperature when the first drop reaches the receiver and again as the last of the liquid comes over. A pure liquid distils over a narrow range, and a wide range points to a mixture.

Frequently Asked Questions

Where should the thermometer bulb sit in the head?
The top of the bulb should be level with the lower edge of the side-arm opening. The bulb is then bathed in vapour on its way to the condenser. Set higher, it reads low. Pushed down toward the boiling liquid, it can read high.

Which version do I need?
Choose the flask cone to match the flask socket and the side-arm cone to match the condenser socket. A B24 flask can feed a B19 or a B24 condenser, and a B19 flask feeds a B19 condenser. Every version has a top socket for the thermometer.

Why does the temperature drop near the end?
When nearly all of the lower-boiling liquid has distilled, less vapour reaches the bulb and the reading falls. That drop marks the end of the fraction. Change the receiver before raising the heat for the next fraction.

Why does nothing come over although the flask is boiling?
The vapour condenses in the head and runs back before it reaches the side arm. Raise the heat a little, or wrap the flask neck and the head loosely in foil to cut heat loss. Then wait for the reading to climb.

Other Heads and Joint Adapters

For a quote, use Add To Cart or send us a message through the contact page.