Distillation Columns, Vigreux Manufacturer,Supplier and Exporter in India

Distillation Columns, Vigreux

Product Code : EL-D-1603
Jlab Export is a leading Distillation Columns, Vigreux Manufacturer,and suppliers in India

A Vigreux column is a straight glass tube whose wall is pinched inward at intervals along its length. It sits between the boiling flask and the still head in a fractional distillation. Vapour condenses and boils again on the pinched glass as it climbs, which separates liquids that boil fairly close together. Two lengths are made, 360 mm and 600 mm, both with a B24 socket and cone.

Specifications

TypeVigreux fractionating column
Effective length360 mm or 600 mm
JointsB24 socket and B24 cone on both lengths
Minimum order quantity50 units
Dispatch timeUsually 3–5 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Fractional Distillation Practicals

The usual student exercise separates ethanol from water. The column goes into the B24 socket of a Flasks, Round Bottom, Short Neck JLab, with a Distillation Heads and thermometer on top. The vapour then passes into a sloping Condensers, Liebig, and students collect small fractions and log the temperature at which each one comes over.

Teachers can run the same mixture with and without the column. When temperature is plotted against volume collected, the step between the two fractions is sharper with the column in place.

Frequently Asked Questions

Should the column be insulated?
Usually yes, in a draughty room or with a liquid that boils high. A wrap of aluminium foil or glass wool cuts heat loss, so the vapour reaches the top instead of falling back. Leave a narrow slit to watch the condensing ring rise.

Why does liquid fill the column and stop the distillation?
The flask is boiling too hard, and the rising vapour holds up the liquid that should run back. This is called flooding. Lower the heat until the column drains, then raise it slowly. A steady rate of about one drop per second from the condenser gives the sharpest separation.

Which length do I need, 360 or 600 mm?
The 600 mm column gives more separating length for liquids that boil close together, but it holds back more liquid and takes longer to warm through. The 360 mm column suits school mixtures and small charges, where liquid held in the column would be a large share.

Can a Vigreux column give pure ethanol from a water mixture?
No. Ethanol and water form an azeotrope, a mixture that boils at a fixed composition, so even the richest fraction still holds some water. A longer column brings the distillate closer to that limit but cannot pass it.

Other Fractional Distillation Glassware

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 14 November 2026


   