Fixit Lever Manufacturer,Supplier and Exporter in India

Fixit Lever

Product Code : EL-PALE-2365
Jlab Export is a leading Fixit Lever Manufacturer,and suppliers in India

The fixit lever is fixed firmly on its spindle and can be held still while the rest of the set-up is adjusted. A vulcanite roller on the central spindle carries 3 pins set at 90°, and the lever fits on one of them. A spring on a rod sliding through the frame presses on the roller to stop it turning. The isotonic model has a cam in place of the after-load screw.

Specifications

Lever mountingFixed to the spindle, on one of the roller pins
RollerVulcanite, with 3 pins set at 90° on the central spindle
Roller lockSpring on a rod sliding through the frame bears against the roller
Isotonic modelCam in place of the after-load screw, without hook and weights
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Organ Bath Practicals with the Fixit Lever

In isolated tissue work the lever sits above an Organ Bath, where a strip of tissue hangs in aerated physiological salt solution at a set temperature. A thread joins the free end of the tissue to the lever. Each contraction then writes a peak on the slow-turning Student Kymographs Digital drum.

Students add an agonist in rising doses to build a dose-response curve, then repeat the series after a blocker and compare the two curves. With the two-unit Isolated Organ Baths Digital, a pair of fixit levers records two tissues on one drum. Work on animal tissue follows the approval of the institution’s animal ethics committee.

Frequently Asked Questions

How is the load set when there are no hook weights?
On the isotonic model a cam takes the place of the after-load screw. Turning the cam sets the point at which the lever rests, so the tissue takes up the lever only when it starts to contract.

What does the spring against the roller do?
It locks the roller. While you raise the tissue holder, level the lever or move the writing point onto the drum, the spring stops the roller from turning. Release it before recording so the lever swings freely.

Why does the roller carry three pins?
The pins sit at 90° to each other, so the lever can be fitted on whichever pin points the right way for the set-up. That lets the writing point meet the drum without moving the whole stand.

Why does the baseline drift during an organ bath run?
The tissue may still be settling, or the bath temperature may not yet be steady. A slack or slipping thread also moves the baseline. Wait for a flat trace before the first dose, and check the knots and the lever lock.

Other Recording Levers