Isolated Organ Baths Digital Manufacturer,Supplier and Exporter in India
Product Code : EL-IOBD-2397
Jlab Export is a leading Isolated Organ Baths Digital Manufacturer,and suppliers in India
Two tissues can be studied side by side in this two-unit isolated organ bath. Its chamber is made of thick clear acrylic sheet, chemically welded, and is heated by 250 W elements under a microprocessor-based digital temperature controller. It comes with two sets of glass inner vessels, oxygen tubes, warming coils, fixit levers and holders.
Specifications
| Bath chamber | Thick transparent acrylic sheet, chemically welded |
| Units | Two (two-unit isolated bath) |
| Heating | 250 W heating elements |
| Temperature control | Microprocessor-based digital controller on a compact control panel |
| Supplied with | Two sets of glass inner vessels, oxygen tubes, warming coils, fixit levers and holders |
| Power | 220 V AC, 50 Hz, single phase |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Parallel Tissue Experiments in Pharmacology
With two inner vessels, one tissue can serve as a time-matched control while the other receives a blocker. Students build agonist dose-response curves on both and compare the shift. Both fixit levers can write on one drum, such as the Student Kymographs Digital, so the two traces share one time base.
The pair of vessels also suits a bioassay, with a standard and an unknown sample tested side by side. Another use is comparing two tissues, such as ileum and uterus, under one agonist. Extra levers are sold separately as the Fixit Lever. Practicals on isolated animal tissue follow the approval of the institution animal ethics committee, and simulations often run alongside them.
Frequently Asked Questions
What are the warming coils for?
Fresh salt solution runs through a coil inside the heated bath before it reaches the inner vessel. It arrives at bath temperature, so washing the tissue between doses does not chill it and shift the baseline.
Can the two vessels run at different temperatures?
No. Both glass inner vessels stand in the same heated acrylic chamber under one digital controller, so they share one temperature. A practical that compares two temperatures needs two separate baths.
What power supply does it need?
It runs on 220 V AC, 50 Hz, single phase, and the heating elements are rated at 250 W. An ordinary earthed lab socket is enough, with the lead kept clear of the wet bench area.
How long should the bath settle before tissue goes in?
Set the temperature on the controller and wait until the display holds steady at the set value. Then let the salt solution in each inner vessel warm through. Tissue hung in a vessel that is still warming gives a drifting baseline.
Can a force transducer be used instead of the levers?
Yes. The fixit levers write on a kymograph. A lab that records with a force transducer and data recorder can tie the tissue thread to the transducer instead, mounted on its own stand above the vessel.
Other Organ Baths and Assemblies
- Organ Bath (single acrylic bath)
- Four Unit Organ Bath (four inner vessels)
- Organ Jar Bath Digital
- Perfusion Langendorff Assembly
For a quote, use Add To Cart or send us a message through the contact page.