ESR Tube Stand Manufacturer,Supplier and Exporter in India
Product Code : EL-PALE-9848
Jlab Export is a leading ESR Tube Stand Manufacturer,and suppliers in India
This ESR set is a stand for erythrocyte sedimentation rate tests that also lets the user fill each ESR tube and adjust its blood level without pouring by hand. The blood column can be brought to the zero mark before the timing starts. It comes in two models and uses glass pipettes that can be cleaned and used again.
Specifications
| Type | ESR stand with filling and level adjustment of the ESR tube |
| Models | Two models |
| Pipettes | Glass, reusable |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
ESR Practical for Physiology Students
The Westergren ESR test is a routine physiology and haematology practical. Students mix blood with a citrate anticoagulant, fill the glass pipette and set the column exactly at zero with the level adjustment. They start a Stop Watch and leave the stand untouched on a level bench.
After one hour they read how far the top of the red cell column has fallen, in millimetres, below the clear plasma. Teachers often set up a second tube that is tilted on purpose, so the class sees how slanting speeds up the fall. Spare ESR Tube stock keeps the practical running when a pipette breaks.
Frequently Asked Questions
Why must the ESR tubes stand exactly upright?
When a tube leans, the red cells slide down the lower wall and collect faster than in a vertical tube. Even a small slant gives a higher reading, so check that the stand is level and every tube sits straight.
Where should the stand be kept during the test?
On a firm bench away from centrifuges, doors, fans and direct sunlight. Vibration and draughts disturb the settling cells, and warmth from the sun or a nearby heater speeds sedimentation, while a cold room slows it.
How do I set the blood column exactly at zero?
Fill the pipette slowly so no air bubbles enter, then use the level adjustment to bring the top of the column to the zero line. A column above or below zero changes the reading, and a bubble breaks the column apart.
How is the reading taken?
Read it after exactly one hour, at eye level. Note the distance in millimetres from the zero mark to the top of the red cell column. Read the top of the red cells, not the thin whitish layer of white cells that may sit above them.
How should the reusable glass pipettes be cleaned?
Rinse each pipette with water straight after use, before blood dries inside. Wash it with a laboratory cleaning solution, rinse it well with distilled water and let it dry standing up. Check the graduations are clear before the next class.
Other ESR and Blood Testing Items
- ESR Tube Stand (for 6 or 12 tubes, spring-loaded tab)
- Haemometer
- Machine Made Capillary
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 20 November 2026