Digital HB Reader LCD Alpha Numeric Manufacturer,Supplier and Exporter in India
Product Code : EL-PALE-9840
Jlab Export is a leading Digital HB Reader LCD Alpha Numeric Manufacturer,and suppliers in India
The HB reader is a small photometer set up for one test: haemoglobin by the cyanmethaemoglobin method. Green light from an LED at 546 nm passes through the diluted sample in a square plastic tube, and a silicon photodiode measures it. A microcontroller converts the reading and shows the result in g/dl on a one-line alphanumeric display, with no calculation needed.
Specifications
| Method | Cyanmethaemoglobin |
| Wavelength | 546 ± 5 nm |
| Light source | Green LED |
| Detector | Silicon photodiode |
| Display | 16 x 1 alphanumeric LCD, result in g/dl |
| Modes | Measurement and Calibration, auto zero |
| Default standard value | 15 g/dl, can be changed in Calibration mode |
| Memory | 40 tests |
| Keypad | 2 x 2 soft touch |
| Sample tubes | Square 10 x 10 mm, plastic; minimum volume 1 ml |
| Power | Mains 220 V ± 10%, 50 Hz, single phase; 12 V DC battery |
| Size and weight | 215 x 150 x 100 mm, 1.5 kg net |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Haemoglobin Practicals for Teaching Labs
A common class exercise compares two methods on the same sample. Students add a measured drop of blood to the cyanide reagent with a Variable Volume Micropipette, using a fresh tip from the Micropipette Tips pack for each sample. After mixing and standing, the solution is poured into the square tube and read. The same blood is then tested by the acid haematin method on a Haemoglobinometer, and the class discusses why the visual result differs.
A second exercise covers calibration. Students read a standard solution and check that the stored value of 15 g/dl matches its label. If a different standard is used, they enter its value in Calibration mode.
Frequently Asked Questions
Why must the diluted sample stand before it is read?
The reagent first converts haemoglobin to methaemoglobin and then to cyanmethaemoglobin, and this takes a few minutes. Reading too early catches the reaction part way, so the result comes out low. Follow the standing time given with your reagent kit.
How is the reader calibrated?
Put a cyanmethaemoglobin standard in a clean tube and read it in Calibration mode. The reader stores 15 g/dl as the standard value by default. If your standard has a different value, enter that value, then return to Measurement mode for samples.
Does the reagent need special handling?
Yes. Cyanmethaemoglobin reagent contains a small amount of cyanide salt. Keep it labelled and capped, never pipette it by mouth, and dispose of used solutions as your laboratory rules require. Wash hands after the practical.
How does this differ from the Sahli method?
In the Sahli method the observer matches a brown colour by eye, so two people can read the same tube differently. The reader measures the light that passes at 546 nm with a photodiode and shows the figure itself, which removes the colour-matching step.
What does the memory store, and can it run without mains?
It keeps the last 40 test results, so a batch can be noted down at the end of the class. It runs on 220 V mains and also takes a 12 V DC battery supply where mains is not at hand.
Other Haemoglobin Instruments
- Haemoglobin Meter
- Haemometer (Sahli-type comparator)
- Haemoglobinometer Digital
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 12 November 2026
