Universal Kymograph With Inbuilt Stimulator Manufacturer,Supplier and Exporter in India
Product Code : EL-PALE-10532
Jlab Export is a leading Universal Kymograph With Inbuilt Stimulator Manufacturer,and suppliers in India
Drum and stimulator are built into one unit in this universal kymograph, so a class can shock a tissue and record its response without a separate stimulator. The drum runs at 8 speeds from 0.12 to 640 mm/s. The stimulator gives single or repeated pulses from 0.5 to 100 Hz at up to 25 V, and a manual of experiments comes with it.
Specifications
| Drum speeds | 0.12, 0.25, 1.25, 2.5, 12.5, 25, 320 and 640 mm/s |
| Stimulator | Inbuilt |
| Stimulus mode | Single or repeat |
| Frequency steps | 0.5, 1, 3, 5, 7, 10, 15, 20, 50 and 100 Hz |
| Voltage steps | 0, 5, 10, 15, 20 and 25 V |
| Pulse width settings | 0.5 and 1.5 |
| Revolution sensor | Infra red, gives feedback to trigger the stimulus |
| Bath mounting | Pre-fitted flexistand for the Muscle and Heart Bath |
| Power use | Very low |
| Supplied with | Manual with experiment instructions |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Physiology and Pharmacology Experiments
For nerve-muscle work, a Muscle and Heart Bath clamps to the flexistand and its electrode leads go to the built-in stimulator. Students record the simple twitch at a fast drum speed, then step the voltage to find threshold and maximal responses. Switching to repeat mode and raising the frequency shows summation, incomplete tetanus and complete tetanus, and a long repeat run shows fatigue.
Pharmacology classes run the drum at its slowest speeds. A strip of isolated tissue in an Organ Bath pulls a Simple Lever, and each dose of an agonist shows as a contraction on the paper. A series of doses gives a dose-response curve, and repeating it after a blocker shows the shift. Colleges carry out animal tissue work under the approval of their animal ethics committee.
Frequently Asked Questions
What does the infra red sensor do?
It counts the revolutions of the drum and sends a signal back to the stimulator. A shock can then be given at the same point on each turn, so successive twitches start at the same place and can be laid side by side for comparison.
Which settings show summation and tetanus?
Use repeat mode at a voltage that gives a maximal twitch. At 0.5 or 1 Hz the twitches stay separate. As the frequency rises they fuse into summation and then incomplete tetanus, and at the upper steps the trace becomes a smooth plateau. The exact step depends on the tissue.
How should the voltage be set for a twitch experiment?
Start at 0 V and give single shocks, moving up one step at a time. The first step that gives a small twitch is the threshold. Keep going until the height stops rising, then record at the step just above that maximal level.
What is the flexistand for?
The flexistand is fitted on the kymograph to carry the Muscle and Heart Bath. The bath, its electrode and its ink-writing lever then sit at the drum, so the pen can be set to touch the paper without a separate stand.
Other Kymographs and Stimulators
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 12 November 2026