Universal Kymograph With Inbuilt Stimulator Manufacturer,Supplier and Exporter in India

Universal Kymograph With Inbuilt Stimulator

Product Code : EL-PALE-10532
Jlab Export is a leading Universal Kymograph With Inbuilt Stimulator Manufacturer,and suppliers in India

Drum and stimulator are built into one unit in this universal kymograph, so a class can shock a tissue and record its response without a separate stimulator. The drum runs at 8 speeds from 0.12 to 640 mm/s. The stimulator gives single or repeated pulses from 0.5 to 100 Hz at up to 25 V, and a manual of experiments comes with it.

Specifications

Drum speeds0.12, 0.25, 1.25, 2.5, 12.5, 25, 320 and 640 mm/s
StimulatorInbuilt
Stimulus modeSingle or repeat
Frequency steps0.5, 1, 3, 5, 7, 10, 15, 20, 50 and 100 Hz
Voltage steps0, 5, 10, 15, 20 and 25 V
Pulse width settings0.5 and 1.5
Revolution sensorInfra red, gives feedback to trigger the stimulus
Bath mountingPre-fitted flexistand for the Muscle and Heart Bath
Power useVery low
Supplied withManual with experiment instructions
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Physiology and Pharmacology Experiments

For nerve-muscle work, a Muscle and Heart Bath clamps to the flexistand and its electrode leads go to the built-in stimulator. Students record the simple twitch at a fast drum speed, then step the voltage to find threshold and maximal responses. Switching to repeat mode and raising the frequency shows summation, incomplete tetanus and complete tetanus, and a long repeat run shows fatigue.

Pharmacology classes run the drum at its slowest speeds. A strip of isolated tissue in an Organ Bath pulls a Simple Lever, and each dose of an agonist shows as a contraction on the paper. A series of doses gives a dose-response curve, and repeating it after a blocker shows the shift. Colleges carry out animal tissue work under the approval of their animal ethics committee.

Frequently Asked Questions

What does the infra red sensor do?
It counts the revolutions of the drum and sends a signal back to the stimulator. A shock can then be given at the same point on each turn, so successive twitches start at the same place and can be laid side by side for comparison.

Which settings show summation and tetanus?
Use repeat mode at a voltage that gives a maximal twitch. At 0.5 or 1 Hz the twitches stay separate. As the frequency rises they fuse into summation and then incomplete tetanus, and at the upper steps the trace becomes a smooth plateau. The exact step depends on the tissue.

How should the voltage be set for a twitch experiment?
Start at 0 V and give single shocks, moving up one step at a time. The first step that gives a small twitch is the threshold. Keep going until the height stops rising, then record at the step just above that maximal level.

What is the flexistand for?
The flexistand is fitted on the kymograph to carry the Muscle and Heart Bath. The bath, its electrode and its ink-writing lever then sit at the drum, so the pen can be set to touch the paper without a separate stand.