• +91-85699-09696

Nerve Muscle Assembly Manufacturer,Supplier and Exporter in India

Nerve Muscle Assembly

Product Code : EL-PALE-10530
Jlab Export is a leading Nerve Muscle Assembly Manufacturer,and suppliers in India

This nerve muscle assembly gathers the drum, stimulating circuit and recording parts a physiology bench needs for frog nerve-muscle and heart work. Its centre is a digital Sherrington recording drum with 7 speeds, metal gears, a built-in timer and alarm, and battery backup. Muscle contractions are written on smoked paper wrapped round the drum.

Specifications

Recording drumDigital Sherrington drum, microprocessor based
Drum speeds7
Drum featuresIn-built timer and alarm, no plastic gears, can run on battery backup
Stimulating partsDu Bois-Reymond induction coil, Du Bois-Reymond key, simple contact key, simple electrode
Levers and holdersCrank myograph, Starling heart lever, adjustable stand, standard and open-sided X blocks
WeightsHook and weight sets of 11 g and 110 g
ClipsDrum paper clips, muscle clip, frog heart clip
Nerve muscle chamber17 x 13 x 3 cm
Also includedN-100 tuning fork, Mariotte bottle and stand, dissection box and tray, pithing needle, 1 packet of kymograph paper
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Nerve-Muscle and Heart Practicals

The first practical is usually the simple muscle twitch. The crank myograph writes the contraction on the drum. The tuning fork writes a time trace beneath it, so the latent period, contraction and relaxation can be measured. Students then move the secondary coil step by step and watch the twitch grow from threshold to maximal. Changing the hook weights shows how load alters the height of contraction and the work done.

With the Starling heart lever and frog heart clip, the same drum records the frog heart beat. Before class the drum paper is coated on a Smoking Burner and Stand, and finished records are fixed in a Varnishing Tray. A Student Stimulator can take the place of the coil where a class prefers set voltage and frequency. Colleges run these practicals under the approval of their animal ethics committee, and many courses use simulations or human-subject practicals alongside them.

Frequently Asked Questions

What is the N-100 tuning fork for?
It marks time on the record. A fork vibrating 100 times a second, held with its writing point on the moving drum, draws one wave every hundredth of a second under the twitch. Counting the waves gives the latent period and the length of each phase.

How is the threshold stimulus found with the induction coil?
Start with the secondary coil far from the primary, keep the Du Bois-Reymond key open, and give single break shocks with the simple contact key. Slide the coil nearer between shocks. The first position that gives a small twitch is the threshold. Past the maximal position the twitch stops growing.

What is the Mariotte bottle used for?
It holds Ringer solution and delivers it at a steady pressure, because the air inlet tube keeps the head of liquid constant as the bottle empties. A steady drip keeps the preparation moist, and in heart work it gives an even inflow.

How do the timer and alarm on the drum help a class?
Many runs need a fixed rest between them, for example between shocks in a fatigue series or between frequencies in a tetanus run. The timer counts that rest and the alarm tells the bench when to record again, so every run starts under the same conditions.

Other Nerve-Muscle Sets and Parts

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us