Ampule Filling and Sealing Device Manufacturer,Supplier and Exporter in India
Product Code : EL-PALE-9850
Jlab Export is a leading Ampule Filling and Sealing Device Manufacturer,and suppliers in India
This device fills glass ampoules with a measured volume of liquid and then seals them in a gas flame. The standard version is worked by hand and fills from 10 ml to 50 ml. It is supplied with its gas burner but without a gas cylinder. A completely motorised version, with adjustment of the fill capacity, is made as well.
Specifications
| Operation | Hand operated; a fully motorised version with capacity adjustment is also made |
| Filling capacity | 10 ml to 50 ml |
| Sealing | Gas burner supplied, gas cylinder not included |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Sterile Products Practicals in Pharmacy Labs
Ampoules for a parenteral practical are first rinsed inside and out on an Ampoule Washing Device and dried. Students then fill a batch with their prepared solution and seal each one in the burner flame straight after filling.
To check the fill, a few sealed ampoules are opened and emptied into a Measuring Cylinder, and the volumes are compared with the set amount. The remaining batch goes on to the clarity check against a black and a white background, and the class records the number of rejects.
Frequently Asked Questions
Should I choose the hand-operated or the motorised version?
The hand-operated device suits teaching labs and small batches, where students should see each step. The motorised version takes over the filling stroke and allows capacity adjustment, which helps when larger batches of the same fill are needed.
What gas supply does the burner need?
The burner comes with the device, but a gas cylinder does not. It is connected to the laboratory’s own gas supply. Check the burner tubing and connections before each session, and light the flame only when the area is clear of solvents.
Why should ampoules be sealed straight after filling?
An open ampoule can pick up dust, fibres and microbes from the air, and its contents can evaporate. Sealing each ampoule as soon as it is filled keeps the solution as it was prepared and stops particles from getting in.
Can thick liquids or suspensions be filled?
Thin solutions fill most evenly. Thick liquids flow slowly and tend to leave drops on the walls, and suspensions settle in the reservoir, so the dose drifts. Stir suspensions between fills and check volumes more often.
What ampoule sizes does it suit?
The hand-operated version fills from 10 ml to 50 ml per ampoule, so it suits ampoules in that range. Choose ampoules whose neck takes the filling tube easily and leaves room above the liquid for a clean seal.
Other Filling and Sealing Equipment
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 12 November 2026