Electrical Machine System Manufacturer,Supplier and Exporter in India
Product Code : EL-LE-11742
Jlab Export is a leading Electrical Machine System Manufacturer,and suppliers in India
Electrical Machine System (code EL-LE-11742) is a complete electrical machines bench, model JL205/032, that runs DC machine, transformer and three-phase asynchronous motor experiments from one training screen with its own AC and DC supplies, digital meters and resistive loads. JLab manufactures the system in Ambala, India; the machines, meters and connecting leads all come with it.
Specifications
| Parameter | Detail |
|---|---|
| Model number | JL205/032 |
| Input supply | Three-phase four-wire, 380 V ±10%, 50 Hz; installed capacity under 1.5 kVA |
| AC supply | Three-phase 0–450 V and single-phase 0–250 V, adjustable (1.5 kVA ganged auto-transformer) |
| DC supply | 220 V (0.5 A) excitation; 0–250 V (2 A) adjustable armature supply |
| Digital meters (3 of each, 0.5 grade) | DC ammeter 2000 mA, DC voltmeter 300 V, AC ammeter 3 A, AC voltmeter 500 V |
| Power and power factor meters | Two; power 1.0 grade, power factor 0.3–1.0, 450 V and 5 A |
| Machines | DC motor, corrected DC dynamometer, AC asynchronous motor, three single-phase transformers (220 V / 0.35 A primary, 55 V / 1.4 A secondary) |
| Working environment | -10 to 40 °C, relative humidity below 85% |
| Size and weight | 1600 × 750 × 1300 mm; 300 kg |
| Quality check | Each machine system is visually inspected before dispatch |
| Pack quantity | Each (sold individually) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Product code | EL-LE-11742 |
| Manufacturer | Jain Laboratory Instruments Pvt Ltd (JLab) — OEM |
| Country of origin | India (made in Ambala, Haryana) |
Experiments Covered
- DC machines: DC generator and DC shunt motor, starting by series resistance or reduced voltage, reversing, and speed control by armature resistance, field resistance or lower armature voltage.
- Single-phase transformer: ratio K, no-load test (I0, P0, U0), short-circuit test (UK, IK, RK) and load characteristic.
- Three-phase transformer: winding polarity and connection group.
- Three-phase asynchronous motor: stator resistance, no-load and short-circuit tests with characteristic curves, parameter calculation and mechanical characteristics.
Machine Rail, Loads and Protection
The machines sit on a stainless steel guide rail over a 20 mm steel plate, with an optical code-disc speed system and digital tachometer. A corrected DC dynamometer measures the output power of the prime mover. Loads come from three-phase adjustable resistors (three groups of 90 Ω × 2 at 1.3 A and three of 900 Ω × 2 at 0.41 A) and a light-box load. If the AC output sees over-current or a direct short circuit, it raises an alarm and cuts the supply, and a timer-alarm recorder logs alarm times. The table top is fire-, water- and wear-resistant high-density board.
Related Electrical Trainers
- Induction Motor Winding Trainer — starting, reversing and star-delta control of an induction motor.
- 1 Phase & 3 Phase Transformer Trainer (Set) — separate bench for single- and three-phase transformer study.
- Power Factor Meter 3ph with Set — analogue three-phase power factor meter for motor circuits.
Other trainers and meters are in Lab Equipment.
Request a Quote
Ask for a quote with Add To Cart or through the contact page; mention the number of benches, your supply voltage and the delivery location.
Last updated: 25 October 2026