Transformer Study System (With PC Interface) (code EL-LE-11712) is a single-phase transformer lab, model JL108/02, that puts a 1 kVA transformer, an auto transformer, moving-iron meters, two wattmeters and a bulb load on one board. It needs no other apparatus for its experiments, so a class can go from polarity checks to a full load test at the same bench. JLab makes the board in Ambala, India.

Specifications

ParameterDetail
ModelJL108/02
TransformerSingle phase, 1 kVA; primary 0–125 V, 0–125 V; secondary 0–125 V, 0–125 V
AC voltmetersTwo 0–300 V and one 0–50 V, moving iron, 72 × 72 mm
AC ammetersTwo 0–5 A and one 0–1 A, moving iron, 72 × 72 mm
WattmetersDynamometer type: 0.4 A, 250 V, 100 W and 4 A, 250 V, 1000 W
Auto transformerInput 230 V, output 0–270 V at 5 A
Protection6 A MCB
LoadTwo 100 W bulbs, three-pin socket for external load
Quality checkEach transformer study system is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-LE-11712
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Experiments on the Single-Phase Transformer

Students work through the polarity test (additive and subtractive), the transformation and turns ratio with the transformer wired for isolation, step-down and step-up, the open-circuit test for iron loss, the short-circuit test for copper loss, and a load test from which efficiency and voltage regulation are worked out. Each test is set out so it can be run on its own or in sequence.

Why the Board Carries Two Wattmeters

The power drawn on no load is small, so the 100 W wattmeter gives a readable deflection in the open-circuit test, while the 1000 W meter takes the short-circuit and load readings. The auto transformer sets the applied voltage for each test, and the 6 A MCB protects the circuit while the bulbs or an external load are switched in.

Related Transformer Trainers

The Lab Equipment section holds the other electrical trainers and meters.

Request a Quote

Send the number of boards, your mains supply and the delivery location through Add To Cart or the contact page.

Last updated: 25 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us