• +91-85699-09696

Concentric Tube Heat Exchanger Manufacturer,Supplier and Exporter in India

Concentric Tube Heat Exchanger

Product Code : EL-HTL-10051
Jlab Export is a leading Concentric Tube Heat Exchanger Manufacturer,and suppliers in India

Concentric Tube Heat Exchanger (code EL-HTL-10051) is a double-pipe exchanger in which hot water from a 3 kW geyser flows through a copper inner tube while the cold stream passes through the surrounding GI pipe, in parallel or counter flow. It comes as a plain tube water-to-water unit or a finned tube water-to-air unit. JLab makes both heat exchanger versions in Ambala, India.

Specifications

ParameterDetail
VersionsA: plain tube, water to water; B: finned tube, water to air
Inner tubeCopper, ID 12.7 mm
Outer pipeGI, ID 15 mm approx., 1.5 m long (A); ID 25 mm approx., 1 m long (B)
Thermometers4 nos.
Flow measurement1 litre measuring flask; orifice meter and manometer for air (B)
Hot waterGeyser, 3 kW, single phase
Electrical supply220 V, 15 A, stabilised single-phase AC
Floor area3 m x 1 m x 1 m height
Quality checkEach heat exchanger is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-HTL-10051
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Plain Tube or Finned Tube

In version A cold water fills the annulus, so liquid wets both sides of the copper wall. In version B cold air takes its place. The air-side film coefficient is far lower than the water side, so the copper tube is finned on its outer diameter to add surface, and the orifice meter and manometer measure the air flow. Both versions read the inlet and outlet temperatures on four thermometers.

Working Out LMTD and Effectiveness

Timing the water into the 1 litre measuring flask gives the mass flow m of each water stream, and Q = m cp (Th1 − Th2) is the heat the hot water gives up from inlet to outlet. With ΔT1 and ΔT2 as the temperature differences between the two streams at each end, LMTD = (ΔT1 − ΔT2) / ln(ΔT1 / ΔT2), and the overall coefficient follows from U = Q / (A × LMTD). Effectiveness is Q divided by the most heat that could pass, Cmin (Th1 − Tc1). Running the cold stream both ways at the same flows shows why counter flow gives the larger LMTD and effectiveness: only in counter flow can the cold outlet end up hotter than the hot outlet.

Other Laboratory Heat Exchangers

The Heat Transfer Lab section of Engineering Lab Equipment lists these exchangers with the conduction and boiling rigs.

Request a Quote

Order through Add To Cart, or send the version (plain or finned tube), the quantity and the delivery address through the contact page for a quotation.

Last updated: 30 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us