Natural Convection Apparatus Manufacturer,Supplier and Exporter in India

Natural Convection Apparatus

Product Code : EL-HTL-10046
Jlab Export is a leading Natural Convection Apparatus Manufacturer,and suppliers in India

Natural Convection Apparatus (code EL-HTL-10046) is a heat transfer unit with a vertical brass pipe, 38 mm OD and 500 mm long, heated from inside by a cartridge heater and housed in a 200 x 200 x 800 mm enclosure with one acrylic side. Seven thermocouples along the pipe give local temperatures for finding both the overall and the local natural convection coefficients. The vertical-pipe convection unit is produced by JLab in Ambala, India.

Specifications

ParameterDetail
Test pipeBrass, 38 mm OD, 500 mm long, with a cartridge heater inside
Thermocouples7, along the length of the pipe
Enclosure200 mm x 200 mm x 800 mm, one side of acrylic sheet
Heater controlDimmerstat
Input measurementVoltmeter and ammeter
Temperature indicatorMultichannel digital
Supplied withTechnical manual
Electricity230 V, 5 A AC, with earthing
Bench area1.5 m x 0.75 m at working height
Quality checkEach convection unit is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-HTL-10046
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Local Coefficients Along the Height

Taking the heat flux as uniform over the surface, q = VI/(πDL), with D = 38 mm and L = 500 mm. Each thermocouple then gives a local coefficient hx = q/(Tx − Ta), where Ta is the temperature of the surrounding air. Air warmed at the surface rises in a boundary layer that thickens towards the top, so the upper thermocouples read hotter and the local coefficient falls with height.

Overall Coefficient and the Enclosure

The mean of the seven readings gives the average surface temperature Ts, and h = VI/[πDL(Ts − Ta)] is the overall coefficient for the pipe. The enclosure keeps room draughts from disturbing the convection currents, while the acrylic side lets the pipe be watched as it runs. Repeating the test at other dimmerstat settings shows h rising slowly as the pipe gets hotter, because the buoyancy that drives the flow grows with the temperature difference. Results can be compared with a textbook correlation of the form Nu = C(Gr Pr)^n, using the pipe length as the characteristic dimension.

Other Natural and Forced Convection Rigs

The unit is one of the Heat Transfer Lab rigs in Engineering Lab Equipment.