Heat Transfer In Natural Convection

Product Code : JL-HTINC-7376
Jlab Export is a leading Heat Transfer In Natural Convection Manufacturer,suppliers and Exporter in India, Heat Transfer In Natural Convection Uruguay (Montevideo), Heat Transfer In Natural Convection Uzbekistan (Tashkent), Heat Transfer In Natural Convection Venezuela (Caracas), Heat Transfer In Natural Convection Vietnam (Hanoi), Heat Transfer In Natural Convection Yemen (Sana'a), Heat Transfer In Natural Convection Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Heat Transfer In Natural Convection
The setup consists of a brass tube fitted in a rectangular duct in a vertical fashion. 
The duct is open at the top and bottom, and forms an enclosure and serves the purpose of undisturbed surrounding. 
An electric heating element is kept in the vertical tube that in turns heats the tube surface. 
The heat is lost from the tube to the surrounding air by natural convection. 
One side of the duct is fitted with a transparent good quality Acrylic window for visualization. 
The temperature of the vertical tube is measure by Temperature Sensors and displayed by a Digital Temperature Indicator with multi-channel switch. 
The tube surface is polished to minimize the radiation losses.
The heat input to the heater is measured by a Digital Ammeter and a Digital Voltmeter and is varied by a variac. 

Experiment:
To determine average heat transfer coefficient.
Utilities Required.
Table for set-up support.
Electricity Supply: I Phase, 220 V AC, 2 Amp.