Heat Transfer In Forced Convection Manufacturer,Supplier and Exporter in India

Heat Transfer In Forced Convection

Product Code : EL-HTIFC-7375
Jlab Export is a leading Heat Transfer In Forced Convection Manufacturer,and suppliers in India

Heat Transfer In Forced Convection (code EL-HTIFC-7375) is a lab set-up for measuring the convective heat transfer coefficient inside a heated pipe while a blower drives air through it. The test pipe is connected to the delivery side of the blower together with an orifice that measures the air flow, and a nichrome wire heater surrounding the test section supplies a constant heat flux. This blower-and-pipe rig is made by JLab in Ambala, India.

Specifications

ParameterDetail
Air supplyBlower unit, test pipe on its delivery side
Air-flow measurementOrifice
HeaterNichrome wire, surrounding the test section
Heat inputConstant heat flux, set through a variac
Power measurementDigital voltmeter and digital ammeter
Surface temperature sensorsFour, embedded on the test section
Air temperature sensorsTwo, in the air stream at the entrance and exit
Quality checkEach rig is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
Product codeEL-HTIFC-7375
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Calculating h From One Set of Readings

Once the temperatures are steady, the heat input is Q = V × I from the digital voltmeter and ammeter. The four surface sensors are averaged to give the pipe surface temperature Ts, and the inlet and outlet air sensors give the mean air temperature Ta = (Tin + Tout)/2. With the heated surface area of the test section A = πdL, the average heat transfer coefficient is h = Q / [A (Ts − Ta)]. Because the orifice reading is taken at the same time, each value of h belongs to a known air flow rate.

Varying the Air Flow and the Heat Input

Two of the experiments compare h at different air flow rates and at different heat inputs. A higher air flow raises h, so the pipe runs cooler for the same Q, while the variac changes the heat flux at a fixed flow. Plotting the four surface temperatures against their position gives the surface temperature distribution along the pipe, which climbs towards the outlet as the air warms up.

Other Convection Set-ups

Find it in the Heat Transfer In Forced Convection category, one of the groups in Heat Transfer Lab Equipment.