Transport Ventilator Manufacturer,Supplier and Exporter in India

Transport Ventilator

Product Code : EL-MV-3951
Jlab Export is a leading Transport Ventilator Manufacturer,and suppliers in India

A transport ventilator keeps a patient ventilated through a patient circuit while the patient is moved between departments. This unit works up to 120 cm H2O at 5–120 breaths/min, with PEEP up to 50 cm H2O, SIMV and a sigh function. The basic unit measures 50 x 23 x 23 cm and weighs about 19 kg.

Specifications

Basic dimensionsW 50 x D 23 x H 23 cm
WeightApprox. 19 kg (42 lb)
Inspiratory flow patternConstant or accelerating; decelerating in pressure controlled ventilation
Internal compressible volume0.075 l
Working pressureUp to 120 cm H2O
Respiratory rate5–120 breaths/min
Inspiratory time20, 25, 33, 50, 67 or 80 % of the respiratory cycle
Pause time0, 5, 10, 20 or 30 % of the respiratory cycle
PEEP0–50 cm H2O
Upper pressure limit15–120 cm H2O
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Transfer Drill Practicals for Students

In a biomedical engineering or nursing skills lab, students assemble the patient circuit and fit an Anti-Static Rebreathing Bag at the patient end as a test lung. They run a leak check, then watch the bag fill and empty as the cycle runs. Kinking the tube for a moment shows how the upper pressure limit ends a breath.

A second session is a mock transfer. Students plan where the ventilator rides on the stretcher, how the circuit is routed and which spares travel with it. Teachers can set the 19 kg unit beside the far lighter Drager Oxylog 1000 Ventilator to discuss size, weight and controls on a transfer.

Frequently Asked Questions

How is a transport ventilator different from an ICU ventilator?
It is built to travel with the patient, so it is smaller and carries a shorter list of modes and screens. This unit still offers PEEP, SIMV, a sigh breath and a choice of inspiratory and pause times, in a 50 x 23 x 23 cm body.

Does a manual resuscitation bag still go on the transfer?
Yes. A ventilator gives set breaths hands-free, while a bag needs a person to squeeze it. Hospitals keep a manual bag with every transport ventilator as a backup, and its use follows the hospital protocol and trained staff.

What training do staff need before using it on transfers?
Staff should know every control on the panel: rate, inspiratory time, pause time, PEEP, the upper pressure limit and the trigger sensitivity. Practice on a test lung in the lab lets them read the machine before they use it with a patient.

What does the sigh function do?
When it is switched on, the ventilator gives a breath with double the set tidal volume once every 100 breaths. It is one of the controls trained staff set according to the hospital protocol.

What does the upper pressure limit do?
It caps the pressure in the circuit during a breath. When the pressure reaches the limit, set between 15 and 120 cm H2O, the breath stops. A blocked or kinked tube brings the pressure up to this limit.

Other Ventilators

For a quote, use Add To Cart or send us a message through the contact page.