Drager Savina Manufacturer,Supplier and Exporter in India
Product Code : EL-MV-3966
Jlab Export is a leading Drager Savina Manufacturer,and suppliers in India
The Drager Savina is a ventilator that gives controlled, assisted, synchronised and spontaneous breaths through a patient circuit. Options add non-invasive ventilation with leak compensation, a pressure-controlled biphasic mode and a graphic screen. A low pressure oxygen inlet lets it run from an independent oxygen source. JLab supplies the unit to hospitals, nursing colleges and biomedical-engineering departments.
Specifications
| Brand | Drager |
| Condition | New |
| Controlled and assisted modes | IPPV (CMV), IPPV Assist (CMV Assist) |
| Synchronised modes | SIMV, SIMV with pressure support |
| Spontaneous modes | CPAP, CPAP with pressure support |
| Optional modes | Pressure-controlled biphasic ventilation, with or without pressure support |
| Optional functions | Non-invasive ventilation with leak compensation, automatic inspiratory flow adaptation in volume modes, graphic monitoring screen |
| Oxygen supply | Low pressure oxygen inlet for an independent source such as an oxygen concentrator (optional) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Supplied by | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Training Exercises for Biomedical Students
A first session covers the names of the parts: the front panel, the gas inlets, the patient circuit and the expiratory port. Students then assemble a circuit, close the patient end with an Anti-Static Rebreathing Bag and watch it fill and empty in a controlled mode. Pinching the inspiratory limb for a moment shows which alarm reacts to a blocked circuit.
Nursing-college teachers can match the mode names on the panel with a mode chart, so students learn that IPPV and CMV mean the same thing. They can also show how an Oxygen Concentrator links to the low pressure oxygen inlet on units fitted with that option.
Frequently Asked Questions
Why does this ventilator list both IPPV and CMV?
They are two names for the same controlled mode, in which the machine delivers every breath. Makers and hospitals use different names for similar modes, so the Savina panel shows both. Staff moving between machines should learn both terms.
What does leak compensation do in non-invasive ventilation?
With a mask there is always some gas escaping around the seal. Leak compensation measures that loss and adds flow, so the delivered breath and the alarms are not thrown off by it. It comes with the optional non-invasive package on this unit.
Can the Savina take oxygen from a concentrator?
Yes, on units with the low pressure oxygen option. That inlet accepts oxygen at low pressure, for example from an oxygen concentrator, so the ventilator does not depend on a piped or cylinder supply for its oxygen.
Is the graphic screen fitted as standard?
No. The graphic screen for ventilation monitoring is an option. It shows breathing values as curves over time, which trainers use to explain how each mode behaves. Ask for it by name if the unit is meant for teaching with waveforms.
Other Ventilators in This Range
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 13 November 2026