Oxygen Concentrator Manufacturer,Supplier and Exporter in India

Oxygen Concentrator

Product Code : EL-OTS-3859
Jlab Export is a leading Oxygen Concentrator Manufacturer,and suppliers in India

A mains-powered concentrator that delivers 0.5–5 litres of oxygen per minute at more than 90% concentration and 0.6 bar outlet pressure. It weighs 20 kg and runs at 40 dB. A mobile dose monitor on a 20 m hose lets the outlet reach a bed away from the unit. Alarms cover mains failure, device failure and low O2 concentration.

Specifications

Flow range0.5–5 litres O2/min
Oxygen outputMore than 90%
Outlet pressure0.6 bar
Noise level40 dB
AlarmsMains failure, device failure, low O2 concentration
Mobile dose monitor hose20 m
Weight20 kg
ConstructionModular, with snap closures and simple filter change
AltitudeKeeps its output at 2000 m
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Alarm and Maintenance Practicals

Biomedical engineering students run the alarm checks first. With the unit working, they pull the mains plug and confirm the mains-failure alarm, then restart it and wait for the output to settle. They open the snap closures, take out the filter and refit it, and time each step with a Digital Stop Watch for the service log.

Nursing students lay out the 20 m hose from the unit to a Multi Functional Nursing Manikin in the next bay. They check the hose for kinks, read the flow control at each setting, and learn to keep a cylinder on a Cylinder Trolley ready for power cuts.

Frequently Asked Questions

What do the three alarms mean?
The mains-failure alarm sounds when the power supply is lost. The device-failure alarm signals a fault inside the unit. The low O2 alarm warns that the gas at the outlet has dropped below its normal concentration. Check the cause before the unit goes back into use.

Is a hum or vibration normal?
A steady low hum from the compressor is normal, and this unit is rated at 40 dB. A new rattle, a louder hum or strong vibration usually points to a loose panel, a blocked filter or a worn part, so have it checked.

Does the long hose affect the oxygen supply?
The 20 m hose of the mobile dose monitor is part of the design, so the unit can stay in one place. Keep it free of kinks, knots and sharp bends, and do not add extra lengths of tubing to it.

Why do water droplets form in the tubing?
Droplets appear when humidified gas cools in the tube, or when a humidifier bottle is filled above its mark. Fill the bottle only to the line, keep the tubing away from cold air streams, and drain or replace wet tubing.

How is the filter changed?
Switch off and unplug the unit, then open the snap closures to reach the filter. Take it out, clean or replace it as the manual directs, and refit it before you restart the unit.