• +91-85699-09696

Oxygen Concentrator Sequal Manufacturer,Supplier and Exporter in India

Oxygen Concentrator Sequal

Product Code : EL-OTS-3858
Jlab Export is a leading Oxygen Concentrator Sequal Manufacturer,and suppliers in India

The Sequal oxygen concentrator, supplied by JLab, routes air through its sieve beds with one mechanically integrated module that has a single moving part. That module takes the place of solenoid valves and valve-sequencing electronics, and the unit has no pressure-reducing regulator. The result is 40 fewer pneumatic and 35 fewer electrical connections.

Specifications

BrandSequal
Valve systemOne mechanically integrated module with a single moving part
Solenoid valvesNone
Valve sequencing electronicsNone
Pressure-reducing regulatorNone
Connections40 fewer pneumatic and 35 fewer electrical connections
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
Supplied byJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Biomedical Engineering Lab Exercises

The Sequal unit suits a lesson on concentrator design. Students trace the air path from the intake filter, through the integrated valve module and the sieve beds, to the outlet. They then open the modular Oxygen Concentrator, with its snap closures, and compare the parts, hoses and wiring joints in each design.

With the power off and the plug pulled, students test the fuse of each unit for continuity with a Digital Multimeter. Nursing students practise the routine checks: clean the intake filter, look for kinks in the tubing, and set up the cannula on a Multi Functional Nursing Manikin.

Frequently Asked Questions

Why does this concentrator have no solenoid valves?
Its air path is switched by one mechanical module with a single moving part. Without solenoid valves or sequencing electronics, there are 40 fewer pneumatic and 35 fewer electrical connections that could leak or come loose.

How is the intake filter looked after?
Switch off and unplug the unit, then take out the intake filter. Wash it in mild soapy water, rinse it and let it dry fully before refitting. A clogged filter starves the compressor of air, so follow the interval in the maker’s manual.

What happens to the supply during a power cut?
A concentrator makes oxygen only while it has power, so the flow stops when the mains fails. Keep a filled cylinder ready as a backup, and switch over by the hospital’s own procedure with trained staff.

What should we check if the output seems low?
Look at the intake filter, the tubing for kinks and leaks, and the airflow around the unit first. If the output stays low, a biomedical engineer should test it with the service manual, since the sieve beds or valve module may need attention.

Other Oxygen Units

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 12 November 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us