Siemens 300A Ventilator Manufacturer,Supplier and Exporter in India
Product Code : EL-MV-3970
Jlab Export is a leading Siemens 300A Ventilator Manufacturer,and suppliers in India
The Siemens 300A Ventilator comes in two parts: a patient unit that handles the gas and a separate user interface with the controls. It covers adult, paediatric and neonatal patients, triggers on flow or pressure, and offers controlled, supported and combined modes plus an automatic mode. JLab supplies it to hospitals and biomedical training labs.
Specifications
| Brand | Siemens |
| Condition | New |
| Patient range | Adult, paediatric and neonate |
| Ventilation modes | Controlled, supported and combined, plus an automatic mode |
| Triggering | Flow and pressure |
| Gas module | O2 and air, with bacteria filtering |
| Patient unit (W x D x H) | 242 x 370 x 240 mm |
| User interface (W x D x H) | 431 x 150 x 325 mm |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Supplied by | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Biomedical Lab Exercises with the 300A
Students trace the gas path from the O2 and air inlets through the gas module to the patient circuit, naming each part. They then fit an Anti-Static Rebreathing Bag at the patient end. Squeezing it gently at the start of a breath shows flow and pressure triggering at work.
In a nursing skills lab, the unit can stand beside a Multi-Functional Nursing Manikin while students practise tracheotomy nursing. They learn where the circuit, filters and controls sit, and how to keep the tubing clear of the bed rails.
Frequently Asked Questions
What is the difference between flow triggering and pressure triggering?
Both let the patient start a breath. With pressure triggering, the ventilator waits for a small drop in circuit pressure caused by the effort. With flow triggering, it watches for a change in the flow passing through the circuit. The 300A can use either method.
What does the automatic mode do?
In an automatic mode the ventilator gives controlled breaths until the patient starts to trigger, then switches to supported breaths. If the patient stops triggering, it returns to controlled breaths. The choice of mode follows the hospital protocol and trained staff.
What do controlled, supported and combined modes mean?
In controlled modes the machine delivers each breath. In supported modes the patient starts every breath and the machine helps it along. Combined modes mix set breaths with supported or spontaneous ones, as SIMV does.
Why are the patient unit and the user interface separate?
The patient unit holds the gas module and connects to the circuit, while the user interface carries the controls. Splitting them lets staff place the control panel where it can be seen and reached. The patient unit measures 242 x 370 x 240 mm.
Other Ventilators in the Range
For a quote, use Add To Cart or send us a message through the contact page.