LP10 Ventilator Manufacturer,Supplier and Exporter in India
Product Code : EL-MV-3964
Jlab Export is a leading LP10 Ventilator Manufacturer,and suppliers in India
This portable ventilator has a pressure control knob for pressure-limited, time-cycled ventilation. Its lower internal resistance cuts the breathing effort a patient needs in SIMV mode. It runs from internal and external batteries, and it is made for continuous use with little maintenance, at home or on a ward. JLab supplies this ventilator on enquiry under the legacy model name LP10.
Specifications
| Pressure control | Knob for pressure-limited, time-cycled ventilation |
| SIMV | Lower internal resistance for less breathing effort |
| Power | Internal and external battery operation |
| Supply | On enquiry |
| Operation | Continuous, low maintenance |
| Build | Portable |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Supplied by | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Leak Test and Circuit Change Practicals
Home-care training starts with the leak test. Students fit a new circuit, block the patient end with an Anti-Static Rebreathing Bag and run the test, then loosen one joint on purpose and run it again to see the failure. After that they change the circuit from start to finish against a checklist, timing each other.
For the pressure control knob, the teacher turns it up and down while the class watches how far the test bag fills on each breath. The machine can also stand beside the LP6 Ventilator so students compare the two front panels and their controls.
Frequently Asked Questions
When should a leak test be run?
Run it before the ventilator is used on a patient and again after every circuit change. A test after cleaning or after a fall is also good practice, since a small crack in a part may not show.
What if the leak test fails?
Check that the exhalation valve is seated and that every joint, cap and filter is pushed home. Run the test again. If it still fails, fit a new circuit and test once more before calling the home care company or the biomedical team.
What does the pressure control knob do?
It sets the pressure limit for pressure-limited, time-cycled breaths. Each breath rises to that pressure and ends when the set time runs out. The setting itself is chosen by trained staff under the prescription.
How should the outside be cleaned?
Switch off and unplug the unit, then wipe the case with a cloth just damp with the cleaner your provider or hospital names. Keep liquid out of the ports and vents, and never spray the panel directly.
How do I keep the batteries ready for use?
The unit runs on internal and external batteries. Keep it plugged in between uses so the batteries stay charged, and check the external battery before every trip away from mains power.
Other Portable Ventilators
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 20 November 2026
