Drager Oxylog 1000 Ventilator Manufacturer,Supplier and Exporter in India
Product Code : EL-MV-3965
Jlab Export is a leading Drager Oxylog 1000 Ventilator Manufacturer,and suppliers in India
The Drager Oxylog 1000 is a small emergency ventilator that is time-cycled, volume-controlled and pressure-limited. JLab supplies this gas-driven unit, which runs on medical oxygen at 2.7–6 bar and weighs 3.15 kg. Minute volume runs from 3 to 20 L/min and frequency from 4 to 54 per minute, both smoothly variable.
Specifications
| Brand | Drager |
| Condition | New |
| Type | Time-cycled, volume-controlled, pressure-limited emergency ventilator |
| Minute volume | 3–20 L/min, smoothly variable |
| Ventilation frequency | 4–54 /min, smoothly variable |
| Drive gas | Medical O2, or compressed air in exceptional cases |
| Supply pressure | 2.7–6 bar (40–88 psi) at 60 L/min |
| Dimensions (W x H x D) | 215 x 90 x 215 mm (8.5 x 3.5 x 8.5 in), excluding handle |
| Weight | 3.15 kg (7.3 lb) |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Supplied by | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Cylinder and Transfer Practicals for Paramedic Students
Students fix an oxygen cylinder upright on a Cylinder Trolley, fit the regulator and connect the supply hose. They read the cylinder gauge, attach an Anti-Static Rebreathing Bag as the test lung and check the circuit for leaks. A paper exercise follows: estimate how long a given cylinder lasts, counting the drive gas the unit uses as well as the gas it delivers.
Teachers can set it beside the Transport Ventilator to compare a small gas-driven unit with a heavier one that offers more modes.
Frequently Asked Questions
How long will an oxygen cylinder last on it?
Divide the usable gas in the cylinder by the gas the unit consumes per minute. A gas-driven ventilator uses drive gas on top of the gas it delivers, so the figure is lower than the minute volume alone suggests. Keep a reserve for delays.
Can it run on compressed air?
Medical oxygen is the normal drive gas. Compressed air can be used only in exceptional cases. In both cases the supply must reach 2.7–6 bar at the inlet.
When should the cylinder be changed?
Change it before it runs low, not when it is empty. Staff follow the hospital or service protocol on the lowest gauge reading allowed before a transfer starts, and carry a full spare on long journeys.
What do time-cycled, volume-controlled and pressure-limited mean?
Time-cycled means each breath ends after a set time. Volume-controlled means the unit delivers a set volume. Pressure-limited means the breath stops rising once it reaches a set pressure, for example when the circuit is blocked.
Why do cylinder gauge readings change on a cold or hot day?
Gas pressure rises and falls with temperature, so a cylinder moved from a warm room to a cold vehicle shows a lower reading. Check the gauge again after a few minutes in the new place.