Puritan Bennett 7200 Series Ventilator Manufacturer,Supplier and Exporter in India

Puritan Bennett 7200 Series Ventilator

Product Code : EL-MV-3956
Jlab Export is a leading Puritan Bennett 7200 Series Ventilator Manufacturer,and suppliers in India

The Puritan Bennett 7200 Series is a microprocessor-controlled intensive care ventilator with its own display screen. JLab supplies it with pressure support and pressure control ventilation, and with monitoring of graphics, respiratory mechanics and auto-PEEP. An RS-232 port sends data out of the machine, and a humidifier and a metabolic monitor are available as options.

Specifications

BrandPuritan Bennett
ConditionNew
ControlMicroprocessor, with display screen
Gas deliveryPressure support and pressure control ventilation
Patient monitoringGraphics, respiratory mechanics, auto-PEEP
CommunicationsRS-232 port and digital communications interface
OptionsMetabolic monitor, humidifier
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
Supplied byJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Monitoring Demonstrations for Respiratory Therapy Students

With an Anti-Static Rebreathing Bag as the test lung, a teacher can show how the graphics screen draws pressure and flow as the bag fills and empties. Squeezing the bag and letting it go changes the pressure and flow curves, and students watch how the trace responds. Where the humidifier option is fitted, they assemble the chamber and follow the water path through the circuit.

Suction is taught in the same session. Students fit a length of Suction Tube and practise the suction position on the Airway Intubation Simulator, then return to the ventilator to reconnect and recheck the circuit.

Frequently Asked Questions

Why does the self-test fail on the leak or compliance step?
The usual cause is a leak at a circuit joint, the humidifier chamber or the exhalation parts. Reseat every connection, check the chamber lid and run the test again. A machine that still fails should go to the biomedical team.

What should be checked if it will not power up?
Check the mains lead, the socket and any fuse or breaker on the unit first. If the display stays dark with power present, the fault is likely in the power supply, which a trained technician should test.

Is a humidifier included?
A humidifier is an option with this unit. Gas from a ventilator is dry, so most circuits use a humidifier or a heat and moisture exchanger, chosen by hospital protocol.

What is the RS-232 port used for?
It is a serial data port. Together with the digital communications interface, it lets the ventilator send readings to an external device, such as a monitor or a computer used for records.

What does auto-PEEP monitoring show?
It shows pressure left in the lungs at the end of a breath when the gas has not fully left before the next breath starts. Trained staff read the figure and act on it under the hospital protocol.

Other Intensive Care Ventilators

For a quote, use Add To Cart or send us a message through the contact page.

Last updated: 13 November 2026


   