Anti-Static Rebreathing Bag Manufacturer,Supplier and Exporter in India
Product Code : EL-HRG-3785
Jlab Export is a leading Anti-Static Rebreathing Bag Manufacturer,and suppliers in India
On an anaesthesia breathing circuit, the rebreathing bag is the reservoir that fills with gas and empties with each breath. Staff watch it move and can squeeze it by hand. This black anti-static bag comes in five capacities: 0.5, 1, 1.5, 2 and 3 litres. Its use on a patient is the work of anaesthesia staff under the hospital’s protocol.
Bag Sizes
| Type | Anti-static rebreathing (reservoir) bag |
| Colour | Black |
| Capacities | 0.5, 1, 1.5, 2 and 3 litres |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Equipment Lab Exercises with Reservoir Bags
Biomedical-engineering and anaesthesia-technician students start by checking capacity. They fill a bag with water from a Measuring Cylinder until it is just full but not stretched, and compare the volume with the size on the bag. Doing this for a 0.5 litre and a 3 litre bag shows why the size has to suit the circuit.
For a leak check, students empty and dry the bag, blow it up with air and close the neck. They press it under water in a Basin 10L and watch the seams and the neck for a line of bubbles. A bag that leaks, or has gone sticky or cracked, is set aside.
Frequently Asked Questions
Why is the bag anti-static, and why is it black?
Rubber that does not conduct can build up a static charge, and a spark near oxygen-rich gas is a fire risk. Anti-static rubber is made able to conduct so the charge drains away. Carbon is the usual additive for this, which is why such bags are black.
How is the right bag size chosen?
The size is the bag’s capacity in litres. Small bags such as 0.5 or 1 litre go on circuits for children, and larger ones on adult circuits. The anaesthetist decides which bag a patient needs, so theatres keep several sizes.
How should a reservoir bag be checked before each list?
Look over the whole surface for cracks, thin spots and stickiness, and make sure the neck is not split. Fit it to the circuit, close the patient end and squeeze. A sound bag holds its shape and the pressure does not fall away.
Why does the bag stay flat or swell tight on a test circuit?
A flat bag usually means gas is not reaching the circuit, or is escaping at a loose joint or an open valve. A bag that swells tight points to a closed relief (APL) valve. Check the gas supply, joints and valve before blaming the bag.