B.P. Bulb

Product Code : EL-HRG-3769
Jlab Export is a leading B.P. Bulb Manufacturer,and suppliers in India

The B.P. bulb is the hand pump of a blood pressure set. Squeezing it pushes air into the cuff. The air release valve at the outlet end then lets the air out slowly while the reading is taken with a stethoscope. This latex-free rubber bulb is offered with or without an inlet check valve, the one-way air inlet at its tail, and fits most blood pressure instruments.

Specifications

ItemRubber squeeze bulb for blood pressure instruments
FinishLatex free
ValveAir release (deflation) valve at the outlet end
OptionsWith or without inlet check valve (one-way air inlet at the tail)
FitsMost blood pressure instruments
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Practicals on Bulbs and Valves

Biomedical and nursing students learn how the bulb works by testing its two one-way valves. They fit it to a Sphygmomanometer Aneroid, Economy with a Velcro Cuff for Sphygmomanometer wrapped round a rolled towel. With the release valve shut, the bulb should spring back after each squeeze and the needle should climb and then stay still.

Next they open the release valve a little at a time and practise letting the needle fall at a slow, steady rate. In a second session they take the inlet end apart, look for dust or lint on the valve, clean it and put it back. Teachers ask them to explain which valve failed when a bulb stays flat or the needle creeps down.

Frequently Asked Questions

Should we order the bulb with or without the inlet check valve?
Both are the same latex-free squeeze bulb, offered with a one-way inlet check valve fitted at the tail or without one. Look at the bulbs now on your sets and order the same form, so a replacement fits the set without changes.

Will this bulb fit our sphygmomanometer?
It is made to fit most blood pressure instruments. Before ordering in bulk, check the outlet against the tube on your set and push one bulb on to make sure the joint is snug and holds air.

Why is the bulb slow to refill after a squeeze?
The inlet check valve at the tail end lets air back in. Dust, lint or a stuck valve slows the refill or stops it. Clean the inlet and check that the valve moves freely, and replace the bulb if it still stays flat.

Why has the rubber turned white or sticky?
A white bloom on stored rubber is common and often wipes off. A sticky, soft or cracked surface means the rubber has perished, and the bulb will soon leak. Store spares cool, dry and out of sunlight to slow this down.