B.P. Apparatus Mercury Manufacturer,Supplier and Exporter in India

B.P. Apparatus Mercury

Product Code : EL-OE-3691
Jlab Export is a leading B.P. Apparatus Mercury Manufacturer,and suppliers in India

This compact B.P. apparatus shows cuff pressure as the height of a mercury column against a graduated scale. It is used with a cuff, a bulb and a stethoscope, and the top of the mercury is read at eye level. Mercury units are also the type often used as a reference when aneroid gauges are checked.

Specifications

TypeMercury column B.P. apparatus
DesignCompact
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Practicals with the Mercury Column

Nursing students begin by setting the apparatus upright on a level table and checking that the mercury stands at zero with the cuff empty. They practise reading the top of the curved mercury surface with the eye level with it, and record readings while listening with a Stethoscope.

In a biomedical lab, the column serves as the reference for a gauge check. Trainees join it to a Sphygmomanometer Aneroid Square Shaped through a Y piece from Connectors T and Y and compare the two at several pressures. The class also goes through the spill procedure, so everyone knows where the spill kit is kept.

Frequently Asked Questions

Where should the mercury sit before a reading?
At zero, with the cuff empty and the apparatus upright. Look at the top of the curved surface with your eye level with it. If the level sits above or below zero, send the apparatus for servicing before use.

Why does the mercury keep rising after pumping stops, or fall back slowly?
The usual cause is a dirty or blocked air filter at the top of the tube, so air cannot move freely in and out. A biomedical technician cleans or replaces it.

What does a broken mercury column mean?
Gaps or bubbles in the column give false readings. Take the apparatus out of use and send it to a trained technician, because rejoining the column means handling the mercury.

Why has the mercury turned dark?
A black film or powder forms on mercury over time. It makes the column hard to read and can clog the tube. The mercury is cleaned by a technician working in a well-ventilated area.

What should be done if mercury is spilt?
Keep people away, do not touch the mercury and never use a vacuum cleaner on it. Follow the institution’s own mercury spill procedure and spill kit, and set the broken unit aside for the staff who handle mercury waste.