• +91-85699-09696

Sphygmomanometer Aneroid Square Shaped Manufacturer,Supplier and Exporter in India

Sphygmomanometer Aneroid Square Shaped

Product Code : EL-OE-3678
Jlab Export is a leading Sphygmomanometer Aneroid Square Shaped Manufacturer,and suppliers in India

Built around a square-cased aneroid gauge with a 14 cm dial face, this sphygmomanometer gives a large scale that can be angled towards the reader. It comes with a two-tube adult latex bladder, a standard latex bulb, an inflation valve with spring and PVC tubing. The big dial suits a desk or bedside where several students follow one reading.

Specifications

GaugeAneroid, square shaped case
Dial face14 cm diameter, adjustable for easy reading
Bladder2-tube adult latex bladder
BulbStandard latex bulb
ValveInflation valve with spring
TubingPVC
Minimum order quantity10 units
Dispatch timeUsually 4–6 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Biomedical Workshop Practicals

Trainee technicians use this gauge to learn the calibration check. They join it to a B.P. Apparatus Mercury through a Y piece from Connectors T and Y, raise the pressure in steps and log both readings at each step. Plotting the difference against pressure shows whether the error is a fixed offset or one that grows up the scale.

A second practical is a strip-down of the air circuit. Students take the bladder, tubing and bulb apart, find a leaking part with soapy water, and refit it using a spare B.P. Bulb where needed.

Frequently Asked Questions

What if the pointer does not come back to zero?
Open the valve fully and let the bladder empty. If the pointer still sits off zero, the gauge needs re-zeroing in the workshop. Do not use its readings until it has been compared with a reference gauge.

What does it mean if the gauge reads high all along the scale?
A steady offset at every point is a linear error and usually shows at zero too. An error that grows or shrinks up the scale is non-linear and points to the linkage inside. Both are found by comparing with a reference at several pressures.

Who should adjust the gauge mechanism?
Only a trained biomedical technician. Correcting the linkage means opening the case and bending small parts by tiny amounts. Users check the zero and report faults, and leave the dial closed.

Can the gauge be used with a cracked cover glass?
No. The cover keeps dust and fingers off the pointer and the dial face. Replace a cracked or missing cover before the gauge goes back into service.

Why choose a 14 cm dial?
A larger face spreads the scale out, so the pointer is easier to follow while the bladder deflates and easier to read from a step away. Teachers find it useful when a group watches one demonstration reading.