The Bird VIP Infant Ventilator is a microprocessor-controlled ventilator for neonatal, infant and paediatric patients. It monitors mean airway pressure, peak inspiratory pressure and I:E ratio, and works with demand or continuous flow. JLab supplies it new, with an air compressor as an option.
Specifications
| Brand | Bird |
| Condition | New |
| Control | Microprocessor |
| Patient range | Neonatal, infant and paediatric |
| Monitoring | Mean airway pressure, peak inspiratory pressure, I:E ratio |
| Tidal volume range | 20 to 760 ml |
| Rate range | 0 to 150 BPM |
| Flow | Demand or continuous |
| Alarms | Alarm package with adjustable loudness |
| Other features | Fibre-optic data link, optional air compressor |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Supplied by | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Neonatal Ventilator Practicals for Students
Nursing students can practise routing an infant circuit to a Neonatal Intensive Care Incubator, keeping the tubing free of kinks and the joints secure. Before the circuit goes near a baby, they learn to name each part and check it on the bench.
Biomedical students can close the circuit with a small Anti-Static Rebreathing Bag as a test lung. As the instructor changes the breath timing, they watch the peak pressure, mean pressure and I:E ratio on the monitor. Teachers can also compare demand and continuous flow, and test the alarm loudness control in a quiet room.
Frequently Asked Questions
What does the I:E ratio on the monitor mean?
It compares the time spent breathing in with the time spent breathing out in each breath. A ratio of 1:2 means expiration lasts twice as long as inspiration. The Bird VIP shows it beside mean and peak pressure, so staff can see how each breath is timed.
What is the difference between demand flow and continuous flow?
With continuous flow, fresh gas passes through the circuit all the time, so a baby can draw a breath from it at any moment. With demand flow, the machine adds gas when it senses the patient trying to breathe. This unit offers both.
What should staff do if water collects in the infant circuit?
Condensed water in the tubing can block flow and set off pressure alarms. It is drained into a water trap or away from the patient end, never back toward the baby, following the hospital protocol and trained staff.
Is the air compressor included?
No. The air compressor is an option. Order it with the ventilator when the room has no piped medical air. Where piped air and oxygen are available, the ventilator is connected to those outlets instead.