• +91-85699-09696

Air Compressor Ventilators Manufacturer,Supplier and Exporter in India

Air Compressor Ventilators

Product Code : EL-MV-3961
Jlab Export is a leading Air Compressor Ventilators Manufacturer,and suppliers in India

This compact compressor supplies clean, dry compressed air to ventilators that take an external air source. An oil-free compressor core keeps oil out of the air path. Several stages of filtering and drying then remove dust and moisture before the air reaches the outlet hose and the ventilator.

Specifications

TypeCompact air compressor for ventilators
OutputClean, dry compressed air
Compressor coreOil-free
Air treatmentMulti-level filtration and dehydration
UseVentilators that work with an external air source
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Biomedical Lab Exercises on Medical Air

Students connect the compressor outlet to the high pressure air inlet of a Siemens 900C Ventilator and follow the air from the intake to the patient circuit. They name each filter and drying stage, and note where water collects and how it is drained.

To show why the core is oil-free, teachers open a Reciprocating Compressor (Actual Cut Section) and point out where an oiled design lubricates its moving parts. A Humidity/Temperature Monitor placed at the intake lets the class log the room air the compressor draws in over a week.

Frequently Asked Questions

Why does a ventilator compressor need to be oil-free?
Air from the compressor goes into the patient circuit. An oil-lubricated design can carry oil mist into that air. An oil-free core leaves no oil in the air path, and the filters then deal with dust and moisture.

Where should the compressor be placed?
Stand it where the intake draws clean room air, away from exhausts, suction outlets, cleaning fumes and dust. Leave space around it for cooling, and keep the outlet hose short and free of kinks.

What happens if the filters and dryer are not serviced?
A clogged filter lowers the output, and a failed drying stage lets water into the hose and the ventilator inlet. Water in the air line can carry bacteria and damage valves, so filters and drains are checked on a fixed schedule.

Which ventilators can it feed?
It works with ventilators that have an inlet for an external air source. Check that the ventilator inlet fitting and its required pressure match the compressor before connection, and run the ventilator self-test once the air is connected.

Is a backup air source needed?
Yes. A single compressor can stop through a power cut or a fault. Hospitals keep a cylinder or pipeline air supply ready as a backup, following their own procedure.