3MHz Function-Pulse Generator with 50MHz Frequency Counter Manufacturer,Supplier and Exporter in India

3MHz Function-Pulse Generator with 50MHz Frequency Counter

Product Code : EL-FG-10388
Jlab Export is a leading 3MHz Function-Pulse Generator with 50MHz Frequency Counter Manufacturer,and suppliers in India

3MHz Function-Pulse Generator with 50MHz Frequency Counter (code EL-FG-10388) is a DDS (Direct Digital Synthesis) generator that sets frequency to 1 mHz resolution up to 3 MHz and offers sine, square, triangle, ramp, pulse and TTL outputs, a library of built-in arbitrary waveforms and internal modulation. It drives 20 Vpp open circuit, reads signals with a 50 MHz counter and shows settings on a TFT colour LCD. JLab manufactures this 3 MHz DDS generator in Ambala, India.

Specifications

ParameterDetail
Maximum frequency3 MHz
TechniqueDDS (Direct Digital Synthesis)
Frequency resolution1 mHz
ModulationInternal
Standard waveformsSine, square, triangle, ramp, pulse, TTL
Built-in arbitrary waveformsSinc, Cardiac, Blackman, Stair Up, Stair Down, Exponential Rise, Exponential Fall, Voice, Noise, Sine Vertical, Alternate Attenuation, Alternate Amplification, Round PM, Absolute Sine
Output20 Vpp (open circuit) with DC offset
Attenuation60 dB
Rise and fall time≤ 20 ns
Frequency counter50 MHz
DisplayTFT colour LCD with amplitude readout; Ethernet optional
Quality checkEach generator is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity1 unit
Dispatch timeUsually 7–10 working days
Product codeEL-FG-10388
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

Why DDS Gives Such Fine Frequency Steps

A DDS generator does not tune an analogue oscillator. It steps through a stored table of waveform samples at a fixed clock rate, and a tuning number, added to a phase accumulator on every clock cycle, decides how fast the table is read. Changing that number by one changes the output frequency by a tiny, fixed amount, which is how steps of 1 mHz become possible and why the frequency holds steady once set.

Built-in Arbitrary Waveforms

Beyond the standard shapes, stored waveforms cover biomedical, audio and mathematical work: Cardiac imitates a heartbeat signal, Voice gives an audio-like pattern, and Sinc, Blackman and the exponential rise and fall curves are mathematical functions. Stair Up and Stair Down give stepped levels. Internal modulation is available without connecting a separate modulation source.

Frequently Asked Questions

Is the 1 mHz resolution the same as 1 MHz?
They are different units. One millihertz (1 mHz) is a thousandth of a hertz, 0.001 Hz, while 1 MHz is a million hertz, so the small m means very fine steps.

Does the generator give 20 Vpp into any load?
The 20 Vpp figure is the open-circuit (O.C.) output. With a load connected the voltage across it is lower, so check the level on a scope.

Other DDS and 3 MHz Generators

Browse Function Generators for every generator, or step up to Test and Measurement Equipment.

Request a Quote

Send the quantity and delivery address through the contact page, noting whether the optional Ethernet port is wanted, or use Add To Cart.

Last updated: 30 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us