Bacteriological Incubator Manufacturer,Supplier and Exporter in India

Bacteriological Incubator

Product Code : EL-BI-2307
Jlab Export is a leading Bacteriological Incubator Manufacturer,and suppliers in India

This bacteriological incubator heats from 5 °C above room temperature up to 80 °C under thermostat control, for growing cultures in Petri plates and tubes. The aluminium or stainless steel inner chamber sits inside a double wall filled with glass wool. A double glass window in the door lets you look at the cultures without letting the warm air out.

Specifications

Inner chamberAluminium or stainless steel sheet
Outer bodyMild steel sheet, powder coated
InsulationGlass wool between the walls
DoorDouble walled, with double glass observation window
Temperature range5 °C above ambient to 80 °C maximum, thermostat control
Temperature stability±1 °C at the set point, under steady conditions
Thermometer and controlsL-shaped thermometer, pilot lamps, on-off switch, temperature control knob
Power supply220 V AC, 50 Hz, single phase
OptionsAir circulating fan, 24 hour timer, digital temperature controller-cum-indicator, with or without computer data logger
Chamber sizes (mm)300 x 300 x 300, 355 x 355 x 355, 455 x 455 x 455, 455 x 605 x 455, 605 x 605 x 455, 605 x 605 x 605, 605 x 910 x 605
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Microbiology Practicals with Broth Cultures

Broth cultures make a good first exercise. Students inoculate nutrient broth in a Glass Culture Test Tube with an Inoculating Loop Nichrome Wire, flaming the loop before and after. After incubation they compare the cloudiness of each tube with an uninoculated control tube.

Teachers can also set a Minimum Maximum Thermometer on a shelf overnight. Next morning students read the highest and lowest values and compare them with the built-in thermometer and the setting on the knob.

Frequently Asked Questions

Where should the incubator stand in the lab?
Place it on a level, firm surface away from doors, windows, air vents and direct sunlight, which all cause temperature swings. Leave a gap behind and beside the cabinet so air can move and the cord can be reached.

How often should the temperature be checked?
Many labs read the thermometer and write it in a log at the start and end of each day. Compare it now and then with a separate reference thermometer, and report any difference so the setting can be corrected.

What should be checked after a power cut?
Note the time of the cut in the log. When power returns, wait for the thermometer to settle back at the set point before trusting it. Decide with your supervisor whether the cultures inside are still fit to read.

Why should plates and tubes not be packed against the walls?
Warm air must move round every item for even heating. A tight stack or a rack pushed against the wall leaves some plates warmer or cooler than the rest. Keep small gaps between stacks and leave the shelf edges clear.

What is the double glass window for?
It lets you check growth or the thermometer without opening the door. Each opening lets warm air escape, and the chamber then needs time to return to its set temperature.