This rotary stand keeps up to 94 pipettes upright in rings around a central axis, and turning it brings any one of them within reach. The lower disc has four concentric troughs with tapered sides and open bottoms that cradle the tips. A matching grid in the upper disc holds each pipette vertical. The stand is moulded in polypropylene.
Specifications
| Capacity | Up to 94 pipettes |
| Material | Moulded polypropylene |
| Rotation | On a central vertical axis |
| Lower disc | Four concentric troughs with tapered sides and open bottoms |
| Upper disc | Grid pattern, concentric with the lower disc |
| Base | Stationary, with an outer ring that keeps drained liquid on top |
| Assembly | Easily taken apart and put back together |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Practicals Using the Rotary Stand
In a college volumetric analysis lab, many groups share one set of pipettes. After the class, the pipettes go through the Pipette Washer (Automatic) and are then stood on the rotary stand to drain, tip down.
At the start of the next practical, each student turns the stand to find the size the method asks for. For an aliquot, that may be a one-mark borosilicate Pipette. Keeping one ring for each size helps the technician see which pipettes are still out at the end.
Frequently Asked Questions
How many pipettes fit, and how are they arranged?
Up to 94. The lower disc has four concentric troughs and the upper disc a matching grid. The pipettes therefore stand in rings around the central axis and stay upright while the stand is turned.
Should pipettes go on the stand straight from the wash?
Give them a final rinse with distilled water first, then stand them tip down. Tap water leaves mineral spots on the glass as it dries. The open bottoms of the troughs let the last drops run off the tips.
How do we spot chipped pipettes before they are used?
Look at each tip as the stand turns past you. The troughs cradle the tips so they do not knock together, but a pipette already chipped will deliver the wrong volume and can cut a hand. Take it out of use at once.
Can clean pipettes stay on the stand between practicals?
For general chemistry work, a dry pipette on the stand is ready for the next class. An open stand leaves pipettes exposed to dust. For work that must stay clean or sterile, move dry pipettes into a closed container such as the Pipette Box.