Refrigerant Hose Manufacturer,Supplier and Exporter in India
Product Code : EL-RACLE-12751
Jlab Export is a leading Refrigerant Hose Manufacturer,and suppliers in India
This set of three charging hoses in red, blue and yellow comes in the longer 150 cm length, with 1/4 in flare fittings. Each hose has its own compact ball valve, so it can be shut off before it is disconnected. That keeps refrigerant in and air out. The hoses are rated for 600 psi working pressure.
Specifications
| Hoses in the set | 3 (one red, one blue, one yellow) |
| Length | 150 cm |
| Flare fittings | 1/4 in |
| Working pressure | 600 psi |
| Valve | Compact ball valve on each hose |
| Minimum order quantity | 10 units |
| Dispatch time | Usually 4–6 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises with Charging Hoses
Students fit the set to the Hydrocarbon Manifold Gauges or the Manifold Gauges For Refrigeration Systems in place of the standard hoses. Blue goes to the low side, red to the high side and yellow to the centre port. The extra reach helps on a cabinet or test rig whose service valves sit far from where the manifold can hang.
During evacuation, students close the ball valve on the yellow hose to isolate one of the Small Vacuum Pumps. They then watch the low-side gauge to see whether the vacuum holds, without the pump hose open to air.
Frequently Asked Questions
What does the ball valve on each hose do?
It closes the hose with a quarter turn. Shut it before disconnecting and the refrigerant in the hose stays inside, while air and moisture stay out. It also lets you isolate the vacuum pump for a vacuum hold test.
Is a 600 psi rating enough for my system?
It suits most systems on R-22, R-134a, R-404A and hydrocarbons. R-410A and R-32 run at higher pressures and use 5/16 in ports, so they call for hoses such as the 800 psi Refrigerant Hose set.
Why choose 150 cm hoses?
The extra length lets the manifold hang clear while the hoses reach service valves at the back or top of a unit. Longer hoses hold more refrigerant, so close the ball valves before disconnecting to avoid losing it.
Are 150 cm hoses a good choice for evacuation?
Long, narrow hoses slow a vacuum pump down, so evacuation takes longer. Many technicians keep a short, clean hose only for vacuum work, so it stays dry and free of oil. Check the gasket in every flare nut before a vacuum job, since a leaking joint lets air in.
Other Hose Sets and Fittings
- Refrigerant Hose (shorter set, without ball valves)
- Hose Adapters
- Valve Core Remover
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 5 November 2026
