• +91-85699-09696

Semi Fowler Bed (Super) Manufacturer,Supplier and Exporter in India

Semi Fowler Bed (Super)

Product Code : EL-HBSR-1986
Jlab Export is a leading Semi Fowler Bed (Super) Manufacturer,and suppliers in India

Sized 2160 x 1015 x 600 mm, this semi-Fowler bed takes a 1980 x 910 mm mattress on a two-section top of perforated CRCA sheet. An electric actuator moves the backrest when the hand remote is pressed. Stainless steel collapsible side railings run along the sides, and the moulded ABS head and foot bows lift off.

Specifications

Overall size2160 L x 1015 W x 600 H mm
Mattress size1980 L x 910 W mm
TopTwo sections of uniformly perforated CRCA sheet
BackrestElectric actuator, worked by a hand remote
Side railingsStainless steel, collapsible
Head and foot bowsMoulded ABS, easily removable
IV rodTelescopic, four locations
CastorsSwivelling, with braking
Frame and finishRectangular mild steel tube, pre-treated and epoxy powder coated
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Function Test and Care Practicals

Biomedical engineering students run a function test on the actuator. They take the backrest from flat to fully raised and back, listening for any jerk or grinding. Then they check that the remote hangs where the railings cannot trap it. They also fold each railing down and up to find the pinch points before a patient is in the bed.

Nursing students then use an Elderly Fully-Functional Nursing Manikin to practise moving a patient up the bed with the backrest flat. They raise the backrest with the remote and bring an Over Bed Table-B into reach.

Frequently Asked Questions

Why might the actuator stop after several long runs?
Bed actuators are built for short runs with rests between them. Many carry a thermal cut-out that stops the motor if it is run again and again, until it cools. Set the backrest in one steady press.

Where are the pinch points on this bed?
At the hinge between the two top sections, under the backrest as it comes down, and where a railing folds. Check that hands, the remote and any tubing are clear before pressing the down button.

How should the castors be set during care?
Lock them whenever the bed is in place at the bedside, so it cannot creep while the backrest moves or a patient is helped in. Release them only to move the bed, then lock them again.

Should the backrest movement ever feel jerky?
No. The actuator drives the backrest at a steady rate. A jerky or noisy movement is a sign for biomedical staff to inspect the actuator, its mountings and the hinge before the bed goes back into use.