• +91-85699-09696

Tablet Making Machine Motorised Manufacturer,Supplier and Exporter in India

Tablet Making Machine Motorised

Product Code : EL-TMM-2450
Jlab Export is a leading Tablet Making Machine Motorised Manufacturer,and suppliers in India

Tablets are pressed one at a time on this motorised machine, a hammer-type single-punch press with its own motor for a 220 V AC, 50 Hz, single-phase supply. On each stroke the die fills with granules, the upper punch comes down to compress them against the lower punch, and the tablet is then lifted out. Spare chrome steel punch and die sets in 6, 9 and 12 mm can be added.

Specifications

TypeSingle-punch, hammer type
DriveBuilt-in motor
Power supply220 V AC, 50 Hz, single phase
Optional toolingSpare chrome steel punch and die sets, 6, 9 and 12 mm
Minimum order quantity1 unit
Dispatch timeUsually 14–18 working days
ManufacturerJLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India

Pharmaceutics Practicals on Tablet Making

A typical class run compares tablets pressed at different settings from one batch of granules. Students press one set at a light pressure and one at a heavy pressure, then test both on a Tablet Hardness Tester and in the Microprocessor Friability Apparatus. Harder tablets usually lose less weight on tumbling but take longer to break up.

For a release study, tablets from the same run go into the Tablet Dissolution Test Apparatus, and the class relates crushing strength to how fast the drug comes out. Finished tablets can then be counted into packs with the Tablet Counter.

Frequently Asked Questions

How do I set the tablet weight?
Tablet weight depends on how much granule fills the die, which is set by how low the lower punch sits at the filling point. Lower it for a heavier tablet and raise it for a lighter one, then weigh a few tablets and adjust again before the full run.

Why do tablet weights vary within one batch?
Uneven granule size and poor flow into the die change how evenly the die fills from stroke to stroke. Sieve the granules to one size range, add a glidant if the method allows it and keep the feed topped up so it never runs low.

What supply does the motor need?
The motor runs on 220 V AC, 50 Hz, single phase, so it works from a standard lab socket of that rating. Make sure the socket is earthed and keep the cable well clear of the moving parts.

How should the machine be cleaned after a practical?
Switch off and unplug it, brush loose powder from the die table and the feed, then take out the punches and die and wipe them clean and dry. A light film of oil on the steel parts before storage stops rust and keeps the punch faces smooth.