• +91-85699-09696

Ventilation System Trainer Manufacturer,Supplier and Exporter in India

Ventilation System Trainer

Product Code : EL-ELA-5451
Jlab Export is a leading Ventilation System Trainer Manufacturer,and suppliers in India

Ventilation System Trainer (code EL-ELA-5451) is a building services engineering trainer that shows how a ventilation system gives individual rooms their required air change rate, and how the ventilation air is heated or cooled by heat exchangers. Transparent acrylic windows and exposed ductwork let students see components that are normally hidden. It is made by Jain Laboratory Instruments Pvt Ltd (JLab) at its works in Ambala, India.

Specifications

ParameterDetail
TypeVentilation system trainer for building services engineering
PurposeShows how a ventilation system achieves the required air change rates in individual rooms
Air treatmentVentilation air can be heated or cooled by heat exchangers
Visible componentsInspection covers, fire dampers, filters, heaters/coolers, louvre damper and other duct components
ConstructionStandard industrial components; transparent acrylic (Plexiglas) windows and exposed ductwork; original function fully retained
EmphasisVentilation rather than air conditioning
Laboratory water supplyHot water for the heating mode or cold water for the cooling mode
Electrical supplyThree-phase mains
ExtensionAdditional module for a room temperature control system
Quality checkEach trainer is visually inspected before dispatch
Pack quantityEach (sold individually)
Minimum order quantity10 units
Dispatch timeUsually 7–10 working days
Product codeEL-ELA-5451
ManufacturerJain Laboratory Instruments Pvt Ltd (JLab) — OEM
Country of originIndia (made in Ambala, Haryana)

How Does It Compare with the JLab Ventilation Trainer?

ModelMain focusListed details
This trainer (EL-ELA-5451)A building ventilation system with heating and cooling of the airStandard industrial components with the original function retained; acrylic windows and exposed ductwork showing inspection covers, fire dampers, filters, heaters/coolers and louvre damper; three-phase mains; hot or cold water supply; additional module for room temperature control
Ventilation TrainerVentilation engineering, with trainees building the system themselvesEffects of bends, branches and regulator flaps on airflow rate, air velocity and pressure loss; inclined tube manometer with two measuring ranges; digital handheld unit for air velocity; pressure measuring glands on the components; fan power shown by a voltmeter and an ammeter

Choose this trainer when the lesson is how a working building ventilation system is laid out and how its supply air is filtered, heated or cooled; choose the Ventilation Trainer when students should assemble the ductwork themselves and measure airflow and pressure loss.

What Is the Ventilation System Trainer Used For?

A building ventilation system supplies fresh air so that each room reaches its required air change rate — the number of times per hour the air volume of the room is replaced. This trainer is used in building services engineering and HVAC courses at ITIs, polytechnics and engineering colleges to show that process on industrial hardware. Because it is assembled from standard industrial components with the original function fully retained, students look at the same parts they will meet on site: inspection covers that give access to the ductwork, fire dampers that close to limit the spread of fire along the ducts, filters that clean the air, heaters and coolers, and a louvre damper that regulates the airflow.

The trainer concentrates on ventilation rather than full air conditioning. A ventilation system is the preliminary stage of an air-conditioning system: it moves, filters, heats or cools the air, while an air-conditioning system can also humidify or dehumidify it. With the additional module, the same ventilation system can be extended into a room temperature control system.

What to Specify When Ordering

  • Electrical supply — the trainer runs on three-phase mains; give your local voltage and frequency in the enquiry.
  • Laboratory water — plan a hot water supply for the heating mode and a cold water supply for the cooling mode at the installation point.
  • Room temperature control — say whether you also want the additional module for a room temperature control system.
  • Related trainers — the Ventilation Trainer, Air Conditioning Test Rig and Handheld Anemometer Digital are separate items that can be quoted on the same enquiry.

Frequently Asked Questions

What is the Ventilation System Trainer used for?
Teaching ventilation in building services engineering. It shows how a ventilation system achieves the required air change rates in individual rooms and how the ventilation air is filtered and then heated or cooled by heat exchangers.

Which components can students see?
Inspection covers, fire dampers, filters, heaters/coolers and a louvre damper, among others. Transparent acrylic windows and exposed ductwork make these normally hidden parts visible while the system keeps its original function.

What services does the trainer need in the laboratory?
A three-phase mains supply, plus hot water when it runs in the heating mode or cold water when it runs in the cooling mode.

Is it an air-conditioning trainer?
It is mainly a ventilation trainer. It heats or cools the supply air, while humidifying and dehumidifying belong to a full air-conditioning system; JLab lists a separate Air Conditioning Test Rig for that stage.

Can the system be used for room temperature control?
Yes, with the additional module. Adding it turns the ventilation system into a room temperature control system, so include the module in your enquiry if your course covers control.

How does it differ from the JLab Ventilation Trainer?
The Ventilation Trainer is listed for trainees to build a ventilation system and measure how bends, branches and regulator flaps affect airflow rate, air velocity and pressure loss. This trainer presents a building ventilation system with heating, cooling, fire dampers and filters on view.

What information is needed for an export quotation?
Send the quantity, the destination country and port or city, your preferred delivery terms (for example FOB or CIF), your three-phase supply voltage and frequency, any packing or labelling requirements, and the tender reference if the order is for a tender.

Who manufactures the Ventilation System Trainer?
Jain Laboratory Instruments Pvt Ltd, trading as JLab, builds it at its works in Ambala, Haryana, India, and quotes for it directly.

OEM Manufacturer

JLab is the trading name of Jain Laboratory Instruments Pvt Ltd, a manufacturer of educational and engineering lab equipment in India, incorporated in 2017 and based on Hargolal Road, Ambala, Haryana. The ventilation system trainer is built at JLab’s own works instead of being bought in from a trader, so training institutes, colleges, dealers and importers deal with the maker directly; each trainer is visually inspected before it leaves, and repeat orders and spare parts are handled by the same team. JLab exports worldwide and ships to buyers in every region — for example Hong Kong in East Asia, Kuwait in the Middle East, Afghanistan in South Asia, Poland in Eastern Europe and Mozambique in East Africa. Institutions buying through a tender can find details on the JLab lab tenders page.

Related Building Services and HVAC Trainers

Browse more trainers in the Educational Laboratory Apparatus section or the wider Laboratory Apparatus range.

Request a Quote

Use the Add To Cart enquiry button, or write through the contact page with the number of trainers, whether you need the room temperature control module, your supply voltage and the delivery destination.

Last updated: 15 October 2026


   

Office Address

Works: 2475-84,
Hargolal Road,Ambala, Haryana

[email protected]

+91-85699-09696

Follow Us