Blood Bank Refrigerator Cabinet Manufacturer,Supplier and Exporter in India
Product Code : EL-BBF-2312
Jlab Export is a leading Blood Bank Refrigerator Cabinet Manufacturer,and suppliers in India
Built as a double-walled cabinet on castor wheels, this blood bank unit holds its chamber at 4–6 °C with a digital controller-cum-indicator. Blood bottles or bags sit in drawers, and the cabinet also suits vaccines, reagents and cultures. Alarms sound for a temperature swing, an open door and a power failure. Five sizes run from 85 l (50 bags) to 400 l (300 bags).
Specifications
| Temperature | 4–6 °C, digital controller-cum-indicator |
| Alarms | Audio-visual temperature alarm, door operation alarm, power failure alarm |
| Construction | Double walled, stainless steel inner chamber, powder-coated mild steel outer, glass wool insulation |
| Doors and lighting | Lifting door with lock, transparent acrylic inner door, lamp lit when the door opens |
| Storage | Drawers for blood bottles or bags |
| Cooling | Sealed compressor with cooling coil through the chamber |
| Power | 220 V AC, 50 Hz, single phase |
| Mobility | Castor wheels |
| Capacities | 85 l (50 bags), 165 l (110 bags), 200 l (160 bags), 280 l (240 bags), 400 l (300 bags) |
| Options | Digital controller with computer data logger, weekly temperature recorder, 3 kVA automatic voltage stabilizer |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 14–18 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises for Biomedical and MLT Students
Students start with the doors and the lamp. They check that the lamp lights each time the lifting door opens and that the acrylic inner door closes flat. Then they load water-filled practice bags into the drawers and leave a Minimum Maximum Thermometer among them overnight. A Temperature and Humidity Data Logger in the next drawer gives a continuous record of the same night to set beside it.
Alarm checks follow. With the cabinet empty, students leave the lifting door open to set off the door alarm, then switch off at the mains to test the power failure alarm. Biomedical students can also trace the cooling circuit from the sealed compressor to the coil and inspect the door gasket.
Frequently Asked Questions
Does this cabinet freeze plasma?
No. Its controller holds 4–6 °C, a chilled range used for whole blood and for items such as vaccines and reagents. Plasma that has to be kept frozen goes in a separate low-temperature freezer.
How are the alarms tested?
Test each alarm on a schedule and log the result. Open the door to check the door alarm and cut the mains to check the power failure alarm. For the high and low temperature alarm, follow the controller manual.
Why are there two doors?
The outer lifting door locks the cabinet. The transparent acrylic inner door lets staff see the drawers without letting much cold air out, and the cabinet lamp lights whenever the door is opened.
Why is a voltage stabilizer offered?
Swings in the mains voltage strain the compressor and can stop it. The optional 3 kVA automatic voltage stabilizer keeps the supply steady on sites where the voltage rises and falls.
What routine care does the cabinet need?
Wipe the stainless steel chamber clean, check that the door gasket seals all round, and keep dust off the condenser so the compressor does not overwork. The optional weekly recorder or data logger gives a paper or computer record.
Other Blood Bank and Cold Storage Units
For a quote, use Add To Cart or send us a message through the contact page.