Blood Tube Roller Mixer Manufacturer,Supplier and Exporter in India
Product Code : EL-BTRM-2319
Jlab Export is a leading Blood Tube Roller Mixer Manufacturer,and suppliers in India
Blood in an anticoagulant tube starts to settle soon after it is drawn, so tubes are kept turning on a roller mixer until they are tested. This one rolls tubes and bottles of blood, powder reagents or blood control material, and it can also shake them with a 22 mm swing. Rolling and shaking speeds each adjust from 0 to 80 per minute.
Specifications
| Motions | Rolling, anticlockwise rolling and shaking |
| Rolling speed | 0–80 turns/min, adjustable |
| Shaking speed | 0–80 times/min, adjustable |
| Swing amplitude | 22 mm ± 1 mm |
| Power | 12 W |
| Supply | 220 V ± 10%, 50 Hz |
| Net weight | 3.6 kg |
| Size | 394 x 266 x 98 mm |
| Minimum order quantity | 1 unit |
| Dispatch time | Usually 7–10 working days |
| Manufacturer | JLab (Jain Laboratory Instruments Pvt Ltd), Ambala, India |
Lab Exercises for MLT Students
A simple settling demonstration shows why the mixer is used. Students fill tubes with a fine chalk suspension in water, lay half of them on the rollers and stand the rest in a Test Tube Rack. After a fixed time on a Digital Stop Watch, the standing tubes show a clear layer on top while the rolled tubes stay cloudy.
In a second exercise they check the speed dial. They mark one tube with a pen, count its turns for one minute and compare the count with the dial setting. They repeat the check for the shaking motion and for anticlockwise rolling, then note how fast each setting can run before the liquid starts to foam.
Frequently Asked Questions
What speed should I use for blood tubes?
Start low and raise the speed only until the blood moves the full length of each tube. Gentle rolling keeps the cells and anticoagulant evenly mixed without foam. The exact setting for a test follows the laboratory’s own method.
Can rolling damage the blood cells?
Gentle rolling does not. Fast shaking, foaming or air trapped in an overfilled tube can break red cells and release haemoglobin into the plasma. Keep tubes capped and avoid speeds that make the sample froth.
When should I use shaking instead of rolling?
Rolling turns the tube about its own length and suits blood tubes kept mixed for a long time. The shaking motion tips the containers through a 22 mm swing, which helps disperse powder reagents and control material in bottles.
Which containers fit the rollers?
Capped tubes and small round bottles that lie flat across the rollers. Flasks, plates and square bottles do not turn on rollers and suit a shaker or rocker instead.
Other Mixers for Blood Samples
For a quote, use Add To Cart or send us a message through the contact page.
Last updated: 13 November 2026